DATE/TIME : 03/06/98 11:16 <br />TYPE : SP <br /> <br />MAJOR REPAIR SEPTIC PERMIT <br /> PERMIT NO <br /> STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-01526 <br />ISSUED <br />03/06/1998 <br />03/06/1999 <br />2 <br /> <br /> MAJOR SEPTIC REPAIR PERMIT <br /> <br />This property has been evaluated for a septic system repair permit for feasibility to repair <br />an existing septic system for a RESIDENTIAL building. Based on the results of this study, <br />site approval has been granted, This approval is specific to the area tested, and the system <br />must be installed in the immediate area of the test pits. <br /> <br />Soils in the approved area shall not be altered or modified by cutting, filling, or other <br />activities which would impede the successful operation of the septic system, Observe all <br />required setback/separation distances during the installation of the system, <br /> <br />Keep this document with your records~ Give a copy of this permit to the septic system <br />installer prior to the installation of the system. Any deviation from the approved plan <br />must have prior approval from this office. <br /> <br />The following construction specifications shall apply to the installation of the septic system: <br /> TYPE OF REPLACEMENT SYSTEM: STANDARD <br /> <br /> MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br /> LINEAL FEET OF DP~AINFIELD: 300 <br /> TYPE OF DISTRIBUTION: EQUAL <br /> DISPOSAL TRENCH DEPTH: 18INCHES, MININUM: 24INCHES, MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: 6INCHES <br /> MINIMUM SOIL BACKFILL: 6INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br /> The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot <br /> centers and with no line exceeding 125 feet in length. The trenches and perforated <br /> pipe are installed level (+/- one inch) and contoured to follow the natural ground <br /> surface. <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1, THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON MARCH 2, <br /> 1998. SOIL CONDITIONS AT THE TEST PITS ARE SUITABLE TO CON- <br /> SIDER STANDARD SYSTEM DRAINFIELDS. CONSTRUCT THE DRAINFIELDS <br /> WITHIN THE IMMEDIATE AREA OF THE TEST PITS, OBSERVE ALL SET- <br /> BACK AND SEPARATION DISTANCES, USE CARE NOT TO AL~ER THE <br /> NATURAL TOPSOIL WITHIN THE DRAINFIELD SITES PRIOR TO IN- <br /> STALLATION, THE SEPTIC TANK AT THE EXISTING HOUSE MUST BE <br /> PUMPED AND PROPERLY ABANDONED UPON CONNECTION TO THE NEW <br /> SYSTEM, SUBMIT A COPY OF THE PUMPING RECEIPT AND COMPLETED <br /> ABANDONMENT FORM TO OUR OFFICE, REFER TO SIT EPLAN DATED <br /> MARCH 3. 1998. USE FILTER FABRIC TO COVER THE DRAINROCK IN <br /> THESE LOAMY SOILS, <br />2. THE ATTACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection, The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br />2, THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities. Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected, <br />4, THIS SYSTEM MUST BE INSPECTED AND APPROVED PRIOR TO BACKFILL <br /> When work is complete and ready for inspection, call our <br /> Automated Inspection Request line at 373-4427 to request an <br /> inspection. Enter the number "801" for a PRE-COVER inspec- <br /> tion, You may leave a message for the inspector if desired. <br /> Be sure the System Record form with the As-Built drawing is <br /> on the job or in our office when the inspection is requested <br /> An inspection should be completed within seven (7) days. <br /> <br /> <br />