My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SESPEXIS - 1500969
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
SESPEXIS - 1500969
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2010 9:56:52 AM
Creation date
10/12/2004 7:04:03 AM
Metadata
Fields
Template:
Permits
Permit Address
11831 VALERIE LN SE
Permit City
Aumsville
Permit Number
555-98-01851
Parcel Number
081W28C 03200
Permit Type
SESPEXIS
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br /> <br /> EXISTING SYSTEM APPROVAL <br />06/22/98 12:00 PERMIT NO <br />SP STATUS <br />R-2 ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-01851 <br />ISSUED <br />06/22/1998 <br />06/22/1999 <br />2 <br /> <br /> EXISTING SYSTEM APPROVAL <br /> <br />A site inspection was made to determine the condition of the existing on-site sewage system <br />located on the property, No evidence of failure Was found and the system appeared to be <br />functioning in a satisfactory manner. The septic tank was pumped and inspected on 12/06/95 <br />by MIKE'S SEPTIC <br /> <br />This notice is issued with the recommendation that the septic tank be pumped and inspected by <br />a licensed septic tank pumper approximately every five years, This notice does not guarantee <br />satisfactory or continuous operation of the existing on-site sewage disposal system, <br /> <br />Planning approval may also be required for any proposed development of the property, <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1, THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON MAY 18, <br /> 1998. THE REVIEW IS IN CONJUNCTION WITH THE PROPOSED <br /> PROPERTY PARTITION. NO APPARENT CONFLICT OR FAILURE WAS <br /> NOTICED. SPACE IS AVAILABLE FOR FUTURE REPAIRS, REFER TO <br /> REVISED SITE PLAN DATED JUNE 18. 1998. OUR RECORDS INDICATE <br /> THAT THE EXISTING SYSTEM WAS INSTALLED JUNE 24, 1980. IT <br /> INCLUDES A 1000 GALLON CONCRETE TANK AND 4-112' DRAINLINES. <br /> WE RECOMMEND THAT THE SEPTIC TANK BE PUMPED ABOLFF EVERY <br /> FOUR TO FIVE YEARS TO EXTEND THE SYSTEM'S USEFUL SERVICE <br /> AS LONG AS POSSIBLE, WE HAVE NO OBJECTION TO THE PARTITION, <br />2. THE A1-FACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection. The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site. <br />3. THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities, Other <br /> activities such as logging, excavating or filling, driveway <br /> ~lacement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval, <br /> The areas of. the initial septic system and the future repair <br /> system must both be protected. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.