DATE/TIME : 05/27/98 09~29 <br />TYPE : SP <br /> <br />MAJOR REPAIR SEPTIC PERMIT <br /> PERMIT NO <br /> STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-04119 <br />ISSUED <br />05/27/1998 <br />05/27/1999 <br />2 <br /> <br />MAJOR SEPTIC REPAIR PERMIT <br /> <br />This property has been evaluated for a septic system repair permit for feasibility to repair <br />an existing septic system for a RESIDENTIAL building, Based on the results of this stuc[y. <br />site approval has been granted. This approval is specific to the area tested, and the system <br />must be installed in the immediate area of the test pits. <br /> <br />Soils in the approved area shall not be altered or modified by cutting, filling, or other <br />activities which would impede the successful operation of the septic system. Observe all <br />required setback/separation distances during the installation of the system, <br /> <br />Keep this document with your records. Give a copy of this permit to the septic system <br />installer prior to the installation of the system, Any deviation from the approved plan <br />must have prior approval from this office, <br /> <br />The following construction specifications shall apply to the installation of the septic system: <br /> <br />TYPE OF REPLACEMENT SYSTEM: STANDARD <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 C~A[LONS <br /> LINEAL FEET OF DRAINFIELD: 450 <br /> TYPE OF DISTRIBUTION: SERIAL <br /> DISPOSAL TRENCH DEPTH: 24INCHES, MININUM: <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: 6INCHES <br /> MINIMUM SOIL BACKFILL: 12INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br />24INCHES, MAXIMUM <br /> <br />The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot <br />centers and with no line exceeding 125 feet in length. The trenches and perforated <br />pipe are installed level (+/- one inch) and contoured to follow the natural ground <br />surface, <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON MAY 22, <br /> 1998. SOIL CONDITIONS AT THE TEST PITS ARE MARGINAL FOR A <br /> STANDARD SYSTEM DRAINFIELD. THE SOIL IS SHALLOW TO BEDROCK, <br /> SO THERE IS A MODERATE ROCK HAZARD ASSOCIATED WITH DRAIN- <br /> FIELD CONSTRUCTION. REMOVE LARGE ROCK FROM BACKFILL MATERIAL <br /> THE EXISTING SEPTIC TANK IS EXCESSIVELY DEEP AND SUBJECT TO <br /> GROUNDWATER INFILTRATION, IT MUST BE REPLACED WITH A WATER- <br /> TIGHT TANK BECAUSE GROUNDWATER INFILTRATION MIGHT BE THE <br /> PRIMARY CAUSE OF THE CURRENT PROBLEM. THE EXISTING DRAIN- <br /> FIELD DID NOT APPEAR TO BE AFFECTED BY EXCESSIVE SATURATION. <br /> INVESTIGATION TO CONFIRM WHETHER SEWER LINES ARE BLOCKED <br /> SHOULD BE COMPLETED PRIOR TO CONSTRUCTING THE MAJOR REPAIR. <br />2. THE A~ACHED OPJ~NGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection, The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br />3. THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities, Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected, <br />4, THIS SYSTEM MUST BE INSPECTED AND APPROVED PRIOR TO BACKFILL <br /> When work is complete and ready for inspection, call our <br /> Automated Inspection Request line at 273-4427 to request an <br /> inspection, Enter the number "801" for a PRE-COVER inspec- <br /> tion~ You may leave a message for the inspector if desired, <br /> Be sure the System Record form with the As-Built drawing is <br /> on the job or in our office when the inspection is requested <br /> An inspection should be completed within seven (7) days. <br /> <br /> <br />