DATE/TIME <br />TYPE <br />OCCUPANCY <br /> <br /> AUTHORIZATION APPROVAL <br />06/08/98 10:24 PERMIT NO <br />SP STATUS <br />R-3 ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-04035 <br />ISSUED <br />06/04/1998 <br />06/04/1999 <br />2 <br /> <br /> AUTHORIZATION APPROVAL <br /> <br />This Authorization Notice is for an existing system and an inspection of the system <br />determined that it appeared adequate to serve the purpose proposed in the application. No <br />evidence of failure was found, and the system appeared to be functioning in a satisfactory manner, <br />The septic tank was pumped / / , by and was inspected at that time. <br /> <br /> This notice is issued with the recommendation that the septic tank be pumped and inspected by <br />a licensed septic tank pumper approximately every five years. <br /> <br /> This notice does not 9uarantee satisfactory or continuous operation of the existing on-site <br />sewage disposal system. Planning approval may be required for the proposed development of the <br />property, <br /> <br /> CUI~IM~NIS AND CONDIIIUNS <br /> <br /> I, THIS SEPTIC REVIEW WAS COMPLETED BY Z.EWING ON 5/20/98. THE <br /> EXISTING DRAINFIELD WAS INSTALLED IN 1997 AS A REPAIR FOR <br /> THE EXISTING TWO BEDROOM DWELLING. THE SYSTEM APPEARS TO BE <br /> FUNCTIONING SATISFACTORILY AT THIS TIME WITH ON EVIDENCE OF <br /> SYSTEM FAILURE, THE SYSTEM IS APPROVED FOR THE NEW 3 BEDROOM <br /> MANUFACTURED HOME. <br /> 2. THE A~ACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection, The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br /> 3. THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities. Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected. <br /> 4, THIS SYSTEM MUST BE INSPECTED AND APPROVED PRIOR TO BACKFILL <br /> When work is complete and ready for inspection, call our <br /> Automated Inspection Request line at 373-4427 to request an <br /> inspection. Enter the number "801" for a PRE-COVER inspec- <br /> tion, You may leave a message for the inspector if desired, <br /> Be sure the System Record form with the As-Built drawing is <br /> on the job or in our office when the inspection is requested <br /> An inspection should be completed within seven (7) days. <br /> <br /> <br />