DATE/TIME <br />TYPE <br />UGB: <br /> <br /> MANUFACTURED DWELLING PERMIT <br /> : 08/07/98 12:32 <br /> : Not in table, <br />SITE: FD <br /> <br />lO, <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br /> PERMIT NO 98-06279 <br /> STATUS ISSUED <br /> ISSUED 08/07/1998 <br /> TO EXPIRE 02/03/1999 <br /> PAGE 3 <br />portion of handrails shall be not more than 2 5/8 inches in <br />cross-sectional dimension, or the shape shall provide an <br />equivalent gripping surface. Handrails shall be mounted <br />between a minimum of 30 inches and a maximum of 38 inches. <br />They shall be continuous the full length of the stairs. <br />Ends shall be returned or shall terminate in newel posts or <br />safety terminals. <br />(R-214.1) <br />A minimum 2' x 3' landing shall be required on each side of <br />an egress door. The floor or landing shall not be more <br />than one and one-half inches lower than the top of the <br />threshold, (R-212) Exception: The landing on the <br />exterior side of an exterior doorway shall not be more than <br />8 and 1/4 inches below the top of the threshold, <br />Porches, balconies or raised floor surfaces located more <br />than 30 in, above the floor or grade shall have guardrail <br />not less than 26 inches in height, Required guardrail shall <br />have intermediate rails or ornamental closures which will <br />not allow passage of an object 6 in. or more in diameter. <br />Horizontal spacing between the vertical members in required <br />guardrails shall be a maximum of 4 inches at the nearest <br />point between the members. (R-214,2) <br /> ART OF AN EXISTING HOME IS BEING REMOVED FOR PLACEMENT OF A <br />MANUFACTURED DWELLING, THE RECREATION ROOM, BATH AND PATIO <br />IS TO REMAIN. THE EXISTING AREA BE~EEN THE RECREATION ROOM <br />AND THE NEW MANUFACTURED DWELLING WILL BE REMOVED AND A NEW <br />DECK CONSTRUCTED BETWEEN. <br />THE DECK WILL REQUIRE A SEPAP~qTE BUILDING PERMIT IF THE DIST <br />ANCE FROM THE TOP OF THE DECK TO GP~qDE IS GREATER THAN 30" <br />ALL STRUCTUP~qL FRAMING MEMBERS FOR THE DECK WILL HAVE TO BE' <br />OF PRESSURE TREATED MATERIALS OR EQUIVALENT. <br />THE SEPTIC TAMK UNDER THE NEW PLACEMENT OF THE MANUFACTURED <br />DWELLING SHALL BE ABANDONED IN AN APPROVED MANNER, <br />Approved as a replacement dwelling. Existing residence must <br />be removed, demolished or converted to an allowable non- <br />residential use within three (2) ~nths of the occupancy of <br />the replacement dwelling. <br /> <br /> <br />