My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1532374
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1532374
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 1:58:28 PM
Creation date
12/29/2004 8:55:19 AM
Metadata
Fields
Template:
Permits
Permit Address
915 7TH ST N
Permit City
Aumsville
Permit Number
555-99-00316
Parcel Number
082W25AC02500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: AM SITE: <br /> <br /> BUILDING PERMIT <br />02/02/99 14:57 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-00316 <br />ISSUED <br />02/02/1999 <br />08/01/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: 5 Special: <br /> <br />1, CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> AI~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br />2, THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 02/01/99. <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights bs this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. ACCEPTABILITY, This plan review covers the addition to and/ <br /> or alteration of an existing structure. This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review, <br />5, TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect, For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> medifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings. <br />6. THE GAPJ~GE shall be separated from the dwelling and its <br /> attic area by means of 1/2 inch gypsum board applied to the <br /> garage side of the wall. Where the separation is a floor- <br /> ceiling assembly, the structure supporting the separation <br /> shall be protected by 1/2 inch gypsum board or equivalent, <br /> The door between the garage and residence shall be equipped <br /> with solid wood doors not less than 1 2/8 inches in thick- <br /> ness or 20-minute fire-rated, or equivalent, <br /> [Sec. 209.1, 209.2] <br />7, EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches, The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet, [Sec. 310.2, 210.2.1] <br />8, SMOKE DETECTORS / ALTERATIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes. <br /> [Sec. 316.1.1] <br />9. SMOKE DETECTORS shall be installed in each sleeping room, <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements, All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas, Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec. 316.1] <br />10. ENERGY PATH #1 is based on R-21 wall insulation. R-25 under- <br /> floor insulation. R-30 vaulted ceiling insulation. R-38 flat <br /> ceiling insulation, R-15 below grade wood, concrete or <br /> masonry walls, R-15 slab floor edge insulation, R-8 forced <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.