My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1532424
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1532424
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2013 6:51:11 PM
Creation date
12/29/2004 8:55:51 AM
Metadata
Fields
Template:
Permits
Permit Address
23926 BUTTEVILLE RD NE
Permit City
Aurora
Permit Number
555-99-00360
Parcel Number
031W32CA00500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />02/02/99 08:42 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-00360 <br />ISSUED <br />02/02/1999 <br />08/01/1999 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 10 Right: 10 Rear: 20 Special: <br /> <br /> 1, CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 222-1987), <br />2, THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 02/01/99. <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. ACCEPTABILI~. This plan review covers the addition to and/ <br /> or alteration of an existing structure, This review is not <br /> intended to prohibit the building inspector from requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe, Existing construction <br /> not specifically detailed in the submitted plans and struc- <br /> tural calculations is beyond the scope of this review. <br />5. MINIMUM ROOF FRAMING MEMBERS REQUIRED, <br /> <br /> The plans specify 2x6 rafters at 24 inches on center. <br /> This rafter size and spacing is inadequate, The following <br /> minimum size and spacing shall be used: <br /> DF #2 - 2x8 at 12 inches on center. <br /> 2x8 at 16 inches on center. <br /> 2x10 at 24 inches on center. <br /> The 4x4 roof beam is inadequate spanning the 10 feet. The <br /> following is the minimum size beam to use: <br /> DF #2 - 4x8 <br /> <br />6. GROUND CLEARANCE, Wood joists or the bottom of a wood <br /> structural floor closer than 18 inches or wood girders <br /> closer than 12 inches to exposed ground in crawl spaces or <br /> unexcavated areas located within the periphery of the <br /> building foundation shall be pressure treated lumber, <br /> [Sec, 222.1 (1)] <br />7. WOOD COLUMNS shall be approved wood of natural decay <br /> resistance or approved pressure treated wood, Exception: <br /> Post or columns not subject to the weather and supported by <br /> piers projecting 2 inches above the floor or finish grade <br /> and separated therefrom by an approved moisture barrier. <br /> [Sec, 222.1,4] <br />8, THE STRUCTUPJNL SUPPORTS for decks, balconies, porches or <br /> similar structures shall be pressure-treated wood to protect <br /> against decay. [Sec. 322,1] <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.