DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: DT SITE: <br /> <br /> BUILDING PERMIT <br />03/02/99 12:19 PERMIT NO <br />Commercial addition/alteration STATUS <br />B ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-01411 <br />ISSUED <br />02/02/1999 <br />08/29/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2, THIS PLAN REVIEW WAS COMPLETED BY D. MARET ON 3-2-99. <br /> 3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4, Safety glazing material shall be installed in doors and in <br /> locations within a 24-inch arc of either vertical edge of <br /> the door in a closed position, (SEC. 2406.4 #6) <br /> 5, WATER HEATER, The water heater will need siesmic straps <br /> added to prevent displacement of the appliance. Siesmic <br /> straps shall be placed at third points and at least 3 inches <br /> above the lower controls. <br /> 6, A ONE HOUR WALL IS REQUIRED ON THE GARAGE WALL WITHIN SIX <br /> EEET OF THE PROPERTY LINE. ALL OTHER WALLS WHICH DON'T <br /> REQUIRE OPENING PROTECTION (<10') WILL NOT BE REQUIRED TO <br /> HAVE THE ONE HOUR PROTECTION ADDED TO THE STRUCTURE FOR <br /> CHANGE OF OCCUPANCY, ANY OTHER WORK. OTHER THAN ALLOWED BY <br /> THIS REVIEW SHALL REQUIRE THE ONE HOUR FIRE RESISTIVE CONST- <br /> RUCTION. (SEC. 503) <br /> SEE ATTACHED APPROVED METHODS FOR i HR CONSTRUCTION <br /> 7, NO STRUCTURAL CHANGES WILL BE ALLOWED TO THE EXISTING STRUC- <br /> TURE WITHOUT OBTAINING ADDITIONAL PERMITS AND COMPLYING WITH <br /> ADA REQUIREMENTS AND OTHER CODE PROVISIONS. <br /> (SEC, 109 & 3405) <br /> 8, Local Fire Districts may have additional requirements that <br /> affect this project. You are advised to contact the Fire <br /> District before you proceed. <br /> 9. BUILDING YARDS: North:16' <br /> South:16' W/6' TO GARAGE WALL <br /> East:23' <br /> West:30' <br /> BUILDING AREA: Existing:1536 SQ, FT. <br /> Proposed:1536 SQ. FT. <br /> Total:1526 SQ, FT, <br /> OCCUPANT LOAD: First Floor:22 <br /> Second Floor: <br />10. EXIT CONTINUITY, The path of exit travel along a means of <br /> egress shall not be interrupted by any building element <br /> other than a means of egress component. Obstructions shall <br /> not be place in the required width of a means of egress. The <br /> required capacity of a means of egress system shall not be <br /> diminished along the path of exit travel. (SEC. t002.2.5) <br />11, EGRESS ILLUMINATION. Any time a building is occupied, the <br /> means of egress shall be illuminated at an intensity of not <br /> less than I footcandle at the floor level. (SEC. 1003.2.9.1) <br />12, LOCKS OR LATCHES, Regardless of the occupant load served, <br /> exit doors shall be openable from the inside without the use <br /> of a key or any special knowledge or effort. <br /> EXCEPTION: In Group B occupancies, key locking hardware may <br /> be used on the main exit where the main exit consists of a <br /> single door or pair of doors where there is a readily <br /> visible, durable sign on or adjacent to the door stating: <br /> "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS", <br /> (SEC, 1003,3,1.8) <br />12. STAIRS. The stairs at rear of building shall comply with the <br /> ~rovisions as follows; <br /> · 4" minimum - 7" maximum risers and 11" minimum runs <br /> 2, landings at top and bottom 3'x3' 24" 38" <br /> 3. handrails on each side not less than or mere than <br /> <br /> <br />