Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />04/21/99 16:23 PERMIT NO <br />Commercial addition/alteration STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />99-01946 <br />ISSUED <br />04/21/1999 <br />10/18/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: <br /> NO CHANGE IN S~TBACKS <br /> <br />Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 04/12/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 4. APPROVED FOR NON RESIDENTAL USE ONLY, NO R V OR PERSONAL <br /> STORAGE ALLOWED, <br /> 5~ This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA). <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute, Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board. <br /> 1-202-653-7824 (Voce/TDD) or 1-800-USA-ABLE. Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br /> 6. Local Fire Districts may have additional requirements that <br /> affect this project, You are advised to contact the Fire <br /> District before you proceed. <br /> 7, This is a Plan Review covering the TENANT IMPROVEMENT in <br /> Hangar D-3 at the Aurora Airpark. <br /> Plan have been reviewed for compliance with the provisions <br /> of the 1998 Edition ('97 UBC) Oregon Structural Specialty <br /> Code, <br /> 8, MIXED USE OR OCCUPANCY. (OSSC Sec 302) <br /> When a building is used for more than one occupancy purpose, <br /> each part of the building comprising a distinct "occupancy" <br /> as described in Section 301, shall be separated from any <br /> other as specified in Section 302.4, <br /> EXCEPTION: 2. The following occupancies need not be <br /> separated from the uses to which they are <br /> accessory: <br /> 9, MIXED USE OR OCCUPANCY, cont'd: <br /> EXCEPTION 2, CONT'D: <br /> 2,1 Assembly rooms having a floor area of not more than <br /> 750 square feet, <br /> 2,2 Administrative and clerical offices and similar <br /> rooms that do not exceed 25 percent of the floor <br /> of the major use when not related to Group H. <br /> Division 2 & Group H. Division 2 Occupancies. <br /> 2,2 Not applicable to this project, <br /> 2.4 The kitchen serving the dining area of which it is <br /> part, <br /> 2,5 Not applicable to this project, <br />10. TYPE OF CONSTRUCTION. (OSSC Sec 603,1) <br /> The existing building is classified as Type II-N <br /> construction, therefore, materials used shall be as follows: <br /> * Structural elements - noncombustible materials. <br /> * Floor construction - noncombustible materials, provided, <br /> however, that a wood surface or finish may be applied <br /> over such noncombustible materials, <br /> * Walls & permanent partitions - noncombustible materials. <br /> * Materials of constuction and fire-resistive requirmmnts <br /> shall be as specified in Section 601, <br /> * For requirements due to occupancy, see Chapter 3. <br />11. SPECIAL HAZ~RDS, (OSSC Sec 204,7) <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code, <br />12, STAIRWAY CONSTRUCTION. (OSSC Sec 603,4) <br /> <br /> <br />