My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
DWELL - 1595597
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
DWELL - 1595597
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 3:27:36 PM
Creation date
2/15/2005 12:56:32 PM
Metadata
Fields
Template:
Permits
Permit Address
550 MICHAEL WY
Permit City
Aumsville
Permit Number
555-99-02553
Parcel Number
082W25AA03300
Permit Type
DWELL
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: AM SITE: <br /> <br /> DWELLING PERMIT <br />04/26/99 08:20 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-02553 <br />ISSUED <br />04/26/1999 <br />10/23/1999 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 8 Right: 8 Rear: 8 Special: <br /> <br />10. A~IC VENTS. <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> AI~FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS PLAN REVIEW was completed by D, MARET ON 4-22-99. <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code. <br />2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. GROUNDING ELECTRODES. When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall be met to provide for a grounding electrode system: <br /> 1. Uncoated No, 4 reinforcing bar installed not less <br /> 20 feet in length encased with a minimum of 2 inches of <br /> concrete. <br /> 2, An uncoated No. 4 reinforcing bar stubbed up at least <br /> 12 inches above the floor plate line and tightly attached to <br /> the reinforcing bar located in the footing. The spliced lap <br /> of the staubbed up bar to the footing shall be a minimum of <br /> 12 inches. (See Section 4108,1.2) [Sec, 403.4] <br />5. LOT DRAINAGE, Lots shall be provided with adequate drainage <br /> and shall be graded so as to drain surface water away from <br /> foundation walls. The grade away from foundation walls shall <br /> fall a minimum of 6 inches within the first 10 feet. Where <br /> lot lines, walls or other physical barriers prohibit <br /> 6 inches of fall within 10 feet, drains or other approved <br /> means shall be provided to ensure positive drainage. <br /> [Sec. 401,2] <br />6. ON GPJ~DED SITES, the toe of any exterior foundation shall <br /> extend above the elevation of the street gutter at point of <br /> discharge or the inlet of an approved drainage device a <br /> minimum of 12 inches plus two percent, The Building Official <br /> may approve alternate elevations, provided it can be <br /> demonstrated that required drainage to the point of <br /> discharge and away from the structure is provided at all <br /> locations on the site, [Sec. 401.6:1.4] <br />7. BEAMS. Provide a minimum of 3 inches of bearing for beams <br /> or girders that bear on masonry or concrete. The ends of <br /> beams or girders that enter masonry or concrete or walls <br /> shall be provided with a minimum one half inch of clearance <br /> on the top, sides and ends, or shall be of pressure treated <br /> materials, [Sec, 322.1. 502,4] <br />8, UNDERFLOOR DRAINS, The finished grade of the underfloor <br /> surface may be located at the bottom of the footing; however <br /> where there is evidence that the groundwater table can rise <br /> to within 6 inches of the finished floor at the building <br /> ~erimeter or where there is evidence that the surface water <br /> oes not readily drain away from the building site, the <br /> grade in the underfloor space shall be as high as the <br /> outside finished grade, unless an approved drainage system <br /> is provided, [Sec, 409,4] <br />9, TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect, For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection, All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings, <br /> Provide screened attic vents with a net free <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.