Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />04/19/99 13:10 PERMIT NO <br />Resident. addition/alteration STATUS <br />U-1 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-02645 <br />ISSUED <br />04/19/1999 <br />10/16/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: Right: 20 Rear: 20 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center~ Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS PLAN REVIEW WAS COMPLETED BY D. MARET ON 4 19-99, <br />3~ Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />4. Approved for private non-commercial use only, <br />5~ B~E, A 4 inch thick base course consisting of clean graded <br /> sand, gravel, or crushed stone shall be placed on the pre- <br /> pared subgrade when the slab is below grade, <br /> (SEC. 505,2.2) <br />6. CONCRETE SPECIFICATIONS. Basement walls and foundations not <br /> exposed to the weather, basement slabs and interior slabs on <br /> grade, except garage floor and steps exposed to the weather <br /> shall have a minimum compressive strength of 2500 psi, <br /> Basement walls, foundation walls, exterior walls, and other <br /> veritical concrete work exposed to the weather, porches. <br /> carport slabs, and steps exposed to the weather, and garage <br /> floor slabs shall have a minimum specified compressive <br /> strength of 3000, Concrete shall be air entrained, Total <br /> air content (percent by volume of concrete) shall not be <br /> less than 5 percent or more than 7 percent. [Sec. 402.2, <br /> Table 402.2] <br />7, LANDING / EXTERIOR DOOR. A minimum $ foot x 3 foot landing <br /> shall be required on each side of an egress door, The floor <br /> or landing shall not be more than 1 and 1/2 inches lower <br /> than the top of the threshold. Exception: The landing at <br /> the exterior doorway shall not be more than 8 1/4 inches <br /> below the top of the threshold. [Sec. 312.1] <br />8. SMOKE DETECTORS / ALTEP~qTIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes, <br /> [Sec. 316.1.1] <br />9. NON-HEATED STRUCTURE, This structure is being reviewed as a <br /> non-heated structure, If the building is to be heated, <br /> apply for an addendum to these plans by submitting revised <br /> plans showing how this structure will meet the requirements <br /> of the Oregon Energy Code, Apply before starting construc- <br /> tion. <br /> <br /> <br />