My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SESPNEW - 1596494
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
SESPNEW - 1596494
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2010 9:17:57 AM
Creation date
2/15/2005 1:11:10 PM
Metadata
Fields
Template:
Permits
Permit Address
140 4TH ST W
Permit City
Detroit
Permit Number
555-99-03427
Parcel Number
105E02AD06400
Permit Type
SESPNEW
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SEPTIC PERMIT <br />DATE/TIME : 07/02/99 12:35 PERMIT NO <br />TYPE : SP STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />99-02427 <br />ISSUED <br />07/02/1999 <br />07/01/2000 <br />2 <br /> <br />SEPTIC PERMIT <br /> <br />This property was previously evaluated 00/00/0000 for the feasibility to install a <br />septic system for a RESIDENTIAL building site. Based on the results of this study, site <br />approval was granted. The approval is site specific to the area tested, and the septic <br />system must be located in the immediate area of the test pits, unless otherwise authorized <br />by this office, A new site evaluation may be required if the system is proposed for a <br />different area on the property. <br /> <br />This approval was given on the basis that the lot or parcel will not be further partitioned <br />or subdivided and that conditions on this property and on adjacent properties are not altered <br />in any manner which would prohibit the issuance of a permit. Soils in the approved area <br />shall not be altered by cutting, filling, or other developmental activities which would <br />impede the successful operation of the initial or replacement absorption systems. Failure <br />to comply with the above items may void this approval, <br /> <br />The site evaluation approval runs with the land. but the permit is non-transferable and non- <br />refundable. <br /> <br />Keep this document with your records, Show this permit to the septic installer prior to <br />installation of the system. Any deviation from the approved plan must have prior approval from <br />this office. <br /> <br />The following construction specifications shall apply to the installation of the initial <br />septic system: <br /> <br />TYPE OF INITIAL SYSTEM: SEEPAGE TRENCH <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br /> LINEAL FEET OF DRAINFIELD: 212 <br /> TYPE OF DISTRIBUTION: SERIAL <br /> DISPOSAL TRENCH DEPTH: 36INCHES. MINIMUM: 36INCHES. MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 24INCHES <br /> DRAIN MEDIA UNDER PIPE: 18INCHES <br /> MINIMUM SOIL BACKFILL: 12INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br />The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot centers <br />and with no line exceeding 125 feet in length. The trenches and perforated pipe are <br />installed level (+/- one inch) and contoured to follow the natural ground surface. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: SAND FILTER <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1, CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 222-1987). <br />2. THIS SEPTIC REVIEW WAS COMPLETED BY LEE GRIMES ON JUNE 18. <br /> 1999, THIS IS A RE-EVALUATION AND STAKEOUT OF THE PROPOSED <br /> SEPTIC SYSTEMS. REFER TO THE REVISED SITE PLAN DATED JULY <br /> 1. 1999, ALTERNATIVE SEEPAGE TRENCHES WILL BE USED AS THE <br /> INITIAL DP2NINLINES AND AN ALTERNATIVE SAND FILTER SYSTEM <br /> FOR FUTURE REPAIRS. NOTE, THE NEED TO SEAL THE SURFACE WATER <br /> RECEPTICAL OR TO RELOCATE IT AS NECESSARY TO MEET MINIMUM <br /> SEPARATION/SETBACK DISTANCES. THE OLD SEPTIC TANK MUST BE <br /> PUMPED AND PROPERLY ABANDONED, SUBMIT A COPY OF ltiE PUMPING <br /> RECEIPT AND COMPLETED ABANDONMENT FORM TO OUR OFFICE, <br />2. THE ATTACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection, The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br />4. THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> <br /> <br />