Laserfiche WebLink
DATE/TIME <br />TYPE <br />UGB: DT <br /> <br /> MANUFACTURED DWELLING PERMIT <br /> : 06/09/99 14:11 <br /> : New Manufactured Dwelling <br />SITE: <br /> <br />10. <br /> <br />11, <br /> <br /> PERMIT NO 99-04307 <br /> STATUS ISSUED <br /> ISSUED 06/09/1999 <br /> TO EXPIRE 12/06/1999 <br /> PAGE 3 <br /> three risers. The handgrip portion of handrails shall be <br /> not more than 2 5/8 inches in cross-sectional dimension, or <br /> the shape shall provide an equivalent gripping surface. <br /> Handrails shall be mounted between a minimum of 30 inches <br /> and a maximum of 38 inches. They shall be continuous the <br /> full length of the stairs, Ends shall be returned or shall <br /> terminate in newel posts or safety terminals, (R-214,1) <br /> A minimum 2' x 3' landing shall be required on each side of <br /> an egress door. The floor or landing shall not be more <br /> than one and one-half inches lower than the top of the <br /> threshold, (R-212) Exception: The landing on the <br /> exterior side of an exterior doorway shall not be more than <br /> 8 and 1/4 inches below the top of the threshold. <br />Porches, balconies or raised floor surfaces located more <br />than 30 in, above the floor or grade shall have guardrail <br />not less than 36 inches in height, Required guardrail shall <br />· have intermediate rails or ocnamental closures which will <br />not allow passage of an object 6 in, or more in diameter, <br />Horizontal spacing between the vertical members in required <br />guardrails shall be a maximum of 4 inches at the nearest <br />~oint between the members. (R-214.2) <br /> ARAGE, See permit #99-04399 for requirements for garage. <br /> <br /> <br />