Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> DWELLING PERMIT <br />07/19/99 10:12 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-04542 <br />ISSUED <br />07/19/1999 <br />01/15/2000 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 58 Left: 20 Right: 8 Rear: 8 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW was completed by J TRUSSELL ON 7-17-99. <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code, <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. GROUNDING ELECTRODES. When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall be met to provide for a grounding electrode system: <br /> 1. Uncoated No. 4 reinforcing bar installed not less <br /> 20 feet in length encased with a minimum of 2 inches of <br /> concrete. <br /> 2. An uncoated No. 4 reinforcing bar stubbed up at least <br /> 12 inches above the floor plate line and tightly attached to <br /> the reinforcing bar located in the footing. The spliced lap <br /> of the staubbed up bar to the footing shall be a minimum of <br /> 12 inches. (See Section 4108,1.2) [Sec. 403.4] <br /> 5, ENG, This structure uses an Engineered Design to meet the <br /> lateral wall bracing requirements of the code. Insure that <br /> all detailed construction requirements shown on the plans <br /> are followed. <br /> 6, TRUSS DESIGN. Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings. <br /> 7. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be more than 44 inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet, The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet, [Sec. 210.2, 210,2,1] <br /> 8. STAIRWAYS shall not be less than 36 inches in clear width at <br /> all points between the handrail height and the required <br /> minimum headroom of 6 feet 8 inches, Minimum width from the <br /> handrail down is 32 inches with one handrail, 28 inches with <br /> two. The minimum required stair tread width is 9 inches. <br /> The maximum stair rise is 8 inches. When risers are closed. <br /> all treads less than 10 inches shall have a uniform nosing <br /> betweem 3/4 inches and 1 1/4 inches. The greatest riser <br /> height/tread depth shall not exced th smallest by more than <br /> 2/8 inch. [Sec. 314.1: 314.2: 314.2,1; 214.3] <br /> 9. HANDPd~ILS having a minimum and maximum height of 30 inches <br /> and 38 inches, respectively, shall be provided on at least <br /> one side of stairways of more than three risers. Alt re- <br /> quired handrails shall be continuous the full length of the <br /> stairs, Ends shall be returned or shall terminate in newel <br /> posts or safety terminals. Exception: Handrails may be <br /> interrupted by a newel post at a turn, and the use of a <br /> volute turnout or starting easing shall be allowed over the <br /> lowest tread. [Sec. 315.1] <br />10. SMOKE DETECTORS shall be installed in each sleeping room, <br /> <br /> <br />