My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1614343
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1614343
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2013 12:32:52 PM
Creation date
4/3/2005 12:45:47 PM
Metadata
Fields
Template:
Permits
Permit Address
10771 LEVERMAN RD SE
Permit City
Aumsville
Permit Number
555-99-04497
Parcel Number
081W29C 03000
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />07/12/99 15:48 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-04497 <br />ISSUED <br />07/12/1999 <br />01/08/2000 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 10 Right: 10 Rear: 20 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> AI~FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY S. Freilinger on 7/12/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4, GAP~qGE DOOR HEADERS. The proposed header shown on the plan <br /> s is too small for the spans and the roof load, Provide <br /> 3 1/8"x12" 22F-V2 glulam beam or a 6x16 DF header minimum or <br /> submitted an addendum proposing an alternate beam for the he <br /> ader. <br /> 5. HEADER AT PATIO DOOR. Provide a minimum of a 4x8 DF #2 head <br /> er. <br /> 6. THE GARAGE shall be separated from the dwelling and its <br /> attic area by means of 1/2 inch gypsum board applied to the <br /> garage side of the wall, Where the separation is a floor- <br /> ceiling assembly, the structure supporting the separation <br /> shall be protected by 1/2 inch gypsum board or equivalent. <br /> The door between the garage and residence shall be equipped <br /> with solid wood doors not less than 1 3/8 inches in thick- <br /> ness or 20-minute fire-rated, or equivalent, <br /> [Sec. 309.1, 209,2] <br /> 7, SMOKE DETECTORS / ALTERATIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as reqUired for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired. <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes. <br /> [Sec, 316,1,1] <br />8. SMOKE DETECTORS shall be installed in each sleeping room. <br /> outside of each separate sleeping area in the immediate <br /> vicinity of the bedrooms and on each additional story of the <br /> dwelling including basements. All detectors located outside <br /> sleeping rooms shall be interconnected such that the <br /> actuation of one alarm will actuate these alarms in the <br /> individual unit and shall provide an alarm which will be <br /> audible in all sleeping areas. Smoke detectors shall be <br /> 110 volt with batter back-up. [Sec. 316.1] <br />9. BP. This structure uses Brace Wall Panels (BP) to meet the <br /> code requirement for lateral wall bracing, Insure that all <br /> BP's are located as indicated on the plans. <br />10. TRUSS DESIGN. Roof trusses are required to be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspeciton. All jobsite cutting or <br /> modification of the roof trusses shall be clearly shown in <br /> the engineers's design calculations and drawings, If trusses <br /> are to be built at the jobsite, submit the engineer's design <br /> and construction plans to the Marion County Building Depart- <br /> ment prior to start of construction and Nave the approved <br /> drawings available at the site for the framing inspection. <br />11. INTERIOR REMODEL. The plans do not indicate complete inform <br /> ation about the extent of the proposed remodel of the interi <br /> or of the ho~. This review does not include approval of th <br /> e interior remodel work or permit for the building, plumbing <br /> electrical or mechanical that will be done, Separate buildin <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.