Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />10/26/99 11:46 PERMIT NO <br />Commerci al addition/alteration STATUS <br />E-1 ISSUED <br />V-1 HR TO EXPIRE <br /> PAGE <br /> <br />99-05258 <br />ISSUED <br />10/26/1999 <br />04/23/2000 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to Follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY T COLEMAN ON 10/6/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. This is a Plan Review covering the construction of the <br /> additions and alterations to the above indicated building. <br /> The plans have been checked for compliance with the <br /> ,provisions of the Oregon State Structural Specialty Code <br /> ('97 UBC) 1998 Edition. <br /> HIGH SCHOOL: THIS BUILDING HAS BEEN SUBDIVIDED INTO SIX <br /> SEPAPJ~TE AREAS BY 2-HOUR FIRE RESISTIVE AREA SEPARATION <br /> WALLS. THE TYPES OF CONSTRUCTION VARY WITH LOCATION. AREAS <br /> "A" AND "B" ARE SHOWN AS 1-HOUR CONSTRUCTION. <br /> SEE FAX TRANSMI~AL DATED 8/26/99 BY WALT BENSMAN FOR <br /> ALTERNATE METHOD CALCULATION FOR AREA INCREASES BASED ON <br /> RELATIVE WALL LENGTH. OK N/ BO <br /> 5, AREAS OF RESCUE ASSISTANCE (RM 810) <br /> WALLS OF AREA OR RESCUE ASSISTANCE SHALL BE SMOKE BARRIERS <br /> OF NOT LESS THAN i HOUR FIRE RESISTIVE CONSTRUCTION, <br /> DOOR 810 SHALL BE 20-MINUTE RATED ASSEMBLY. <br /> (i107) <br /> 6. SEE REVISED DETAILS FOR 2 HOUR AREA SEPARATION WALL AT ROOMS <br /> C8, C9 & C10, STRUCTRAL MEMBERS ARE NOT TO PASS THROUGH <br /> AREA SEPARATION WALLS, <br /> (A2.12) <br /> 7, An approved water supply capable of supplying the required <br /> fire flow for fire protection shall be provided to all <br /> premises, (UFC 903.2) In setting the requirements for fire <br /> flow, the chief may be guided by Appendix III-A (1997 UFC, <br /> 1998 OUFC) <br /> 8, Buildings under construction shall be in accordance with <br /> Article 87 of the Fire Code, Fire protection shall be <br /> provided in accordance with UFC Section 1804. <br /> 9. Portable fire extinguishers shall be provided and installed <br /> in occupancies and locations as set forth in the Fire Code <br /> and as required by the chief. (UFC 1002) <br />10. The mechanical and electrical plans are not covered by this <br /> review. Mechanical and electrical systems are required to <br /> be in compliance with applicable codes. <br />11. CONTACT PERSONS: <br /> <br /> ARBUCKLE COSTIC ARCHITECTS <br /> WALTER BENZMAN <br /> 363 STATE ST, SALEM. OR 97301 <br /> JASON CANE, DEPUTY STATE FIRE MARSHAL <br /> 4760 PORTLAND ROAD NE. SALEM, OR 97305 <br /> <br /> <br />