My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SESPEXIS - 1618557
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
SESPEXIS - 1618557
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2010 10:24:56 AM
Creation date
4/6/2005 7:10:40 AM
Metadata
Fields
Template:
Permits
Permit Address
13771 WISTERIA DR NE
Permit City
Aurora
Permit Number
555-99-07062
Parcel Number
041W11CA00600
Permit Type
SESPEXIS
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br /> <br /> AUTHORIZATION/MINOR REPAIR PERMIT <br />09/09/99 13:57 PERMIT NO <br />SP STATUS <br />R-3 ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />99-07062 <br />ISSUED <br />09/09/1999 <br />09/0B/2000 <br />2 <br /> <br />AUTHORIZATION/MINOR REPAIR PERMIT <br /> <br />This Authorization Notice is For an existing disposal field, and an inspection of the <br />field determined that it appeared adequate to serve the purpose proposed in the application, <br />No evidence of failure was found in the drainfield and the field appeared to be functioning <br />in a satisfactory manner, <br /> <br />This Minor Repair Permit is for replacement of the existing septic tank, and inspection <br />of the property determined that a new tank may be installed to replace the existing tank, <br /> <br />The following specifications shall apply to the installation of the septic tank: <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 <br /> <br />Call for inspection of the new septic tank after the tank has been installed and prior <br />to backfill, This permit is issued with the recommendation that the septic tank <br /> be <br />pumped and inspected approximately every five (5) years. <br /> <br />This notice does not guarantee satisfactory or continuous operation of the existing <br />on site sewage system disposal field, Planning approval may be required for the <br />proposed development of the property, <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS SEPTIC REVIEW WAS COMPLETED BY Z.EWING ON 8/16/99, THE <br /> EXISTING SEPTIC SYSTEM WAS INSTALLED FOR A 2 BEDROOM HOME <br /> AND 200 LINEAL FEET OF DRAINFIELD WAS REQUIRED ACCORDING TO <br /> OUR RECORDS, THE SEEPAGE TRENCH EQUIVALENT OF 200' OF DRAIN <br /> FIELD WITH A TOTAL OF 20" OF GRAVEL IS 114 LINEAL FEET OF <br /> DRAINLINE, THIS IS BASED UPON THE ORIGINAL SIZING CRITERIA. <br /> INSTALL THE DRAINFIELD NO CLOSER THAN lO' FROM THE PROPERTY <br /> LINE AND PLACE NEW HOME NO CLOSER THAN 10' TO THE NEW DRAIN <br /> LINE, <br /> THE EXISTING SEPTIC TANK MUST BE PUMPED AND ABANDONED AT THE <br /> TIME OF SYSTEM INSTALLATION, SUBMIT THE ATTACHED ABANDONMENT <br /> FORM. <br />3, THE ATTACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection. The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br />4, THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities, Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely affect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected, <br />5. SEEPAGE TRENCH systems are installed with a gravel depth <br /> under the drainfield distribution pipe greater than required <br /> for a standard system. They are permitted on lots or parcels <br /> created prior to January 1, 1974, which are inadequate in <br /> size to accommodate a standard system. The above system <br /> specifications indicate the required gravel depth of the <br /> drainfield, <br />6. THE ATTACHED SEPTIC TANK ABANDONMENT FORM MUST BE COMPLETED <br /> AND RETURNED TO OUR OFFICE, The septic system installer <br /> must complete and sign the form and attach a copy of the <br /> receipt from the septic tank pumper for pumping the tank, <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.