BUILDING PERMIT <br />DATE/TIME 11/01/99 08:33 <br />TYPE Resident, addition/alteration <br />OCCUPANCY U-1 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br /> <br />99-07894 <br />ISSUED <br />11/01/1999 <br />04/29/2000 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1. CALL BEF0RE YOU DIG .... IT'S THE LAW, <br /> A~ENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY S, FREILINGER ON 10/20/99. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 4. UNDERFLOOR VENTILATION, Provide at least one square foot of <br /> underfloor ventilation for each 1500 square feet of crawl <br /> space area. The openings shall be covered with a corrosion <br /> resistant wire mesh. At least one such opening shall be <br /> ~rovided within 3 feet of each corner of the building~ <br /> Vents may be omitted on one side. [Sec, 409,1] <br /> 5. CPJ~NL HOLE. Provide an access crawl hole to the underfloor <br /> space, The minimum size opening required is 18 inches by 24 <br /> inches. [Sec, 409.2] <br /> 6. THE GARAGE shall be separated from the dwelling and its <br /> attic area by means of 1/2 inch gypsum board applied to the <br /> garage side of the wall. Where the separation is a floor- <br /> ceiling assembly, the structure supporting the separation <br /> shall be protected by 1/2 inch gypsum board or equivalent. <br /> The door between the garage and residence shall be equipped <br /> with solid wood doors not less than 1 3/0 inches in thick- <br /> ness or 20-minute fire-rated, or equivalent. <br /> [Sec. 309,1. 309.2] <br /> 7, ENERGY PATH #t is based on R-21 wall insulation, R-25 under- <br /> floor insulation, R-30 vaulted ceiling insulation. R-28 flat <br /> ceiling insulation, R-15 below grade wood, concrete or <br /> masonry walls, R-15 slab floor edge insulation, R-8 forced <br /> air duct insulation. 0,40 U-value window class, 0.50 U-value <br /> skylight class, 0.54 U-value main entry door, (with a max- <br /> imum area of 24 square feet) all other exterior doors, in- <br /> cluding the door between the heated dwelling and the un- <br /> heated garage, 0.20 U-value, <br />8. DESCRIPTION. This permit is for replacing a garage, utility <br /> room,storage and bath with new construction. <br />9, TRUSS DESIGN. Roof trusses are required to be designed by <br /> an Oregon registered Engineer or Architect, For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspeciton. All jobsite cutting or <br /> modification of the roof trusses shall be clearly shown in <br /> the engineers's design calculations and drawings. If trusses <br /> are to be built at the jobsite, submit the engineer's design <br /> and construction plans to the Marion County Building Depart- <br /> ment prior to start of construction and have the approved <br /> drawings available at the site for the Framing inspection, <br />lO. A GROUND COVER shall be installed on the ground in the crawl <br /> space. Ground cover shall be 6-mil black polyethylene or <br /> other approved material of equivalent perm-rating, Ground <br /> cover shall be lapped 12 inches at all joints and cover the <br /> entire surface extending full width and length of the crawl <br /> space and turn 12 inches up the foundation wall, [E 401,9,1] <br />Il, GROUND CLEARANCE. Wood joists or the bottom of a wood <br /> structural floor closer than 18 inches or wood girders <br /> closer than 12 inches to exposed ground in crawl spaces or <br /> unexcavated areas located within the periphery of the <br /> building foundation shall be pressure treated lumber. <br /> [Sec. 322.1 (])] <br />12. GUSSETS, The conection of the post to the beams shall be <br /> gusseted, The bottom of the post shall be restrained to <br /> <br /> <br />