My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1658633
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 2
>
Permit - 1658633
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2011 12:18:45 PM
Creation date
7/18/2005 9:21:01 AM
Metadata
Fields
Template:
Permits
Permit Address
21599 DOLORES WY NE
Permit City
Aurora
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
( 5. <br /> <br />( 6. <br /> <br />( 7. <br /> <br />(x) g. <br /> <br />(.x) lO. <br /> <br />¢) il. <br /> <br />Page 2 <br /> <br />Each above.ground tank is required to have a form of construction or device <br />to release excessive internal pressure caused by exposure fires. Total capa- <br />city of emergency venting devices shall he not less than cubic <br />feet of free air per hour. <br /> <br />The tank area is required to he provided with a drainage system~ or dike <br />required having a liquid capacity of --.-- gallons in accordance w. itb <br />Section 2170. <br /> <br />Each tank opening~ exclusive of vents, is required to be provided with an <br />internal or external valve, plug or blind. <br /> <br />All piping~ valves and fittings are required to conform to Section 31. <br /> <br />Ail piping is required to be substantially supported and protected from phy- <br />sical damage and stress arising from settlement, vibration, expansion or <br />traction, etc. <br /> <br />Ail piping is required to be 'tested'befOre being placed i~ service. Hydro- <br />static, testing is required to he 150% of the maximum anticipated pressure <br />of the System. Pneumatic testing is required to be at 110% of the maximum <br />pressure of the system when operating, but not less than 3 psi and not more <br />than $ psi. <br />Electric wiring and equipment is required to conform to the ~ollowing pro- <br />visions of the State Electric Code. <br /> <br />(X) 12. Suitable fire control devices, such as portable fire extinguishers, or hose <br /> connected to a suitable water supply and fitted with fog nozzle~ or other <br /> equipment as follows is required:' Autbo_~i,t_~v having..~urisdiction. <br /> <br />(X) 13. Additional requirements: Final inspection required by District Deputy State <br /> i. Fire Marshal before covering. <br /> <br />The above'installation is subject to inspection'and approval by a representative <br />of this office. <br /> <br />Very truly yours~ <br /> <br />CLYDE W.~ CENTERS <br />State Fire Marshal <br /> <br /> { ~ Jim Ka~/, Supe/visor <br />cc: k~ Mike Boyce, ~istriet Deputy <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.