Permit Address
5700 HUSKEY LN SE
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
9789
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
10. <br /> <br />The grade away from foundation <br />walls shall fall a minimum of 6 <br />in. within the first 10 ft., <br />except as restricted by lot <br />lines where the fall will be a <br />minimum of 6 in. regardless of <br />the horizontal distance <br />available. R-301.3 <br /> <br />Basement walls, foundation <br />~alls, porches, carport slabs <br />and steps exposed to the <br />weather, and garage floor slabs <br />shall have a minimum specified <br />compressive strength of 3000. <br />Table No. R-302.2 <br /> <br />Footings sections: 12 in. wzde <br /> 1 story: 15 In.- 2 story, 18 <br />In. 3 story. Footings shall <br />extend not less than 18 in. <br />below the finish natural grade. <br />R-303 <br /> <br />Foundation walls shall extend <br />at least 8 in . above the <br />finished grade to the founda- <br />tion at all points. R-304.2 <br /> <br />Masonry and concrete foundation <br />walls shall be constructed <br />using the following criteria: <br />R-304.3 <br /> <br />Drains snell be provided around <br />all concrete or masonry founda- <br />tions. Perforated pipe or other <br />approved systems or materials <br />shall be installed at or below <br />the area to be protected and <br />shall d~scharge by gravity or <br />mechan ~cal means into an <br />a~proved drainage system. R~ <br />305.1 <br /> <br />Exterior foundation walls of <br />masonry construction enclosing <br />basements shall be dampproofed. <br />Foundation walls of habitable <br />rooms located below grade shall <br />be waterproofed. R-306.1 <br /> <br />The minimum net area of venti- <br />lation openings shall be not <br />less than 1 sq. ft. for each <br />150 sq. ft. of crawl apace <br />area. Openings shall be within <br />3 ft · of each corner of said <br />building. <br /> <br />An access crawl hole 18 in. by <br />24 ~n. shall be provided to the <br />underfloor space. R-309·2 <br /> <br />The under floor grade sl~all be <br />cleaned of all vegetation and <br />organic materials. R-309.3 <br /> <br />12. <br /> <br />13. <br /> <br />17. <br /> <br />Bathrooms shall be provided <br />with artificial light and an <br />approved mechanical ventila- <br />tion system capable of <br />prodzcing a change Of air <br />every 12 minutes or a window <br />of not less than 3 sq. ft.~ <br />one-half of which must Oe <br />operable· R-203.3 <br /> <br />Every sleeping room shall nave <br />an exterior door or not less <br />than 5.7 sq. ft. of opcnaQle <br />window. 'Phs m~n. net clear <br />opening height shall De 24 <br />znches. The mzn, net clear <br />openlng width shall se 20 <br />inches. The finished sill <br />height shall De not more them <br />44 inches. R-210.2 <br /> <br />All habitable rooms shall De <br />provided ~.~z th aggregate <br />glazing area of no% less than <br />8 percent of the floor area of <br />such rooms. One-half of the <br />required area of glazing shall <br />be openable. <br /> <br />Where bottom of glass l£ght is <br />within 18 in. of floor and all <br />glass doors and wall panels of <br />bathtub a~d shower e~closures, <br />must be of laminated~ tempered <br />or wire glass. R-208.4 <br /> <br />Openings between the garage <br />and residence shall be <br />equipped with solid wood doors <br />not less than 1 3/8 in. in <br />thickness or equivalent <br />209.1 <br /> <br />The garage shall be completely <br />separated from the residence <br />and its attic area by means of <br />1/2 in. gypsum board or <br />equivalent applied to <br />garage side. R-209.2 <br /> <br />Not less than one exit shall <br />be provided from each dwelling <br />unit. The required exlt door <br />shall be a side-hinged door <br />and not less than 3 ft in <br />width and 6 £t 8 in. in hr. R- <br />211 <br /> <br />Stairways shall not be less <br />than 3 ft in clear width, and <br />the headroom shall be 6 ft 8 <br />in min., rlse 8 1/4 max.~ and <br />run of 9 ~n. min. R-213.1 <br /> <br />Handrails having min. and max. <br />heights of 30 in. and 34 in. <br />respectively, measured- <br />vertically from the nosing of <br />the treads, shall be provtded <br />on at least one s~de Of <br />stairways of three or moro <br />r~ses and sha] 1 be cent <br />tile £ull lcngtl~ ~>1 tl~' <br />and snail extend 6 inches <br />beyond the top and bottom <br />rises, Snds shall be returned <br />or shall terminate in newel <br />post or safet) terminals, R- <br />21~.1 <br /> <br /> <br />