Laserfiche WebLink
°~~~a~ <br />~ ~ <br />March 23, 1999 D <br />MAR 2 5 1999 <br />MARION COUN-~y gUpp~RT <br />SERVICES DEPARTAAEM- <br />. . i. ~ j`~- _. <br />Kim Arbuckle, fVA <br />Alan E. Costic, A1A <br />Wal[er E. Bensman, Jr., AIA <br />Clay[on Vorse, AIA <br />Mark M. Fos[er, AU1 <br />Leonard Lodder, AW <br />Richard S. Rothweiler, AIA <br />Jeff Moore, Deputy Fire Marshall ARBUCKLE COSTIC ARCHITECTS, INC. <br />Salem Fi~e Department 363 State Street <br />370 Trade Street SE Salem, OR 97301-3533 <br />Salem, Oregon 97301-3408 503/581-4I14 Fax: 503/58I-3655 <br />E-Mail: acarch@open.org <br />RE: Plan Review Comments <br />Courthouse Square <br />Projed No. 9828 <br />Dear Jeff: <br />We are responding to your plan review comments and trust that each of the issues you have raised will be <br />resolved. <br />asement: <br />1. Standpipe connection to West Stair S141 and East Stair S256 are shown on <br />Drawings M2.1.2 and M2.1.3 4, r~espedlvely. Typically, all standpipe Informatfon <br />is shovm on mechanical drawings. Ar~chitedural drawings show furring-in. <br />2. Revised Drawings A2.1.1 and A2.1.5 a~e attached, showing that the name has been <br />revised to `NW Hallway". Please note that since the projed has been bid. the <br />awa~ded contrad includes the constnaction of Altemate Nos. 1 and 2. Ther~efore~ <br />the wa~~ sepa-~tirig the base bid and Altemate No. 1 will not be construded and the <br />hallway wiil not exist. _ _ _ - <br />'~ ~ <br />First Floor. <br />1• Standpipe oonnedions have been pr+ovided in West Stair S141 and East Stair S256 <br />as shown on Drawings M3.2.2 a~d M3.2.3, respectively. See Basement Note 1` <br />above. - - ~~, <br />~ . . . . . . r '~~ . . ' .. <br />2. The space deflned as `Tr•ansit Wa~ing Room No. 1175" is a multi-purpose ~ce. ` <br />i am preparing a separate letter addressed to Nathan Brown, requesting that this <br />space be posted w~h a ma~aimum oa:uparrt load of 299 persons. The design of the `'; °' <br />space was based on a program of approximately 200 occupants piu~~~hings, -~r : -- <br />1Merior landscaping, and droulation space. If Nathan Brown 1s agreeable~ we wouid - <br />pr~efe~ to leave the occupancy dassification as A3. <br />3. If Room 1175 is classified as an A3 occupancy, we assume the rating is not <br />~equi~d. We will process a change to add panic haMware to 1175D~ 1240A, and <br />S141 C. <br />4. Ha11.1150 is already designed as a 1-hour corridor tunneL <br />5. Exit Passageway 1248 is defined on Sheet G2 as a 2-hour fire rated comdor tunnel. ' <br />The wall assembly may be constructed from any of the 2-hour fire rated partition . <br />systems available from the Gypsum Association Fire Resistance Design Manual, <br />provided the stud cavity is 4". <br />~ <br />