Laserfiche WebLink
IM ROOM NO./ REMARKS COMPLETE <br />NO. LOCATION D <br />16 Computer Incomplete installation of under counter fluorescent lights. <br /> 5277 2 <br />17 Open office Light switch on southwest wall does is inoperative. <br /> 5278 <br />18 Con£ 5208 Li ht switches on north wall not installed. <br />19 Hall 5112 Exit luminaire X1 is not workin <br />20 Open office Light switch on north wall is not installed. <br /> 5126 <br />21 Con£ 5155 Incom lete installation on floor rece tacle/data box. <br />22 Con£ 5174 Incom lete installation on floor rece tacle/data box. <br />23 Corridor 5150 Magnetic door holders not installed to hold door open <br /> ro erl . <br />24 Corridor 5150 Single gang box with no cover and open wires hanging from <br /> ceilin on east side of corridor. <br />25 Corridor 5241 Single gang box with no cover and open wires hanging from <br /> ceilin on west side of corridor. <br />26 Corridor 5241 Magnetic door holders not installed to hold door open <br /> ro erl . <br />27 Elev. Lobby Security camera not installed. <br /> 5240 <br />28 Elev. Lobby Duple~ receptacle on southeast wall not installed. <br /> 5240 <br />29 County Duplex receptable on northwest wall not installed. <br /> Expansion <br /> 5225 <br />30 County Photocell not installed. <br /> Expansion <br /> 5225 <br />31 Treasurer Duplex receptacles not installed at counter. (counter not <br /> 5233 installed . <br />32 Janitor 5244 Disconnect switch and on/off switch not labeled. <br />33 Janitor 5244 Du lex rece tacle is not GFI as noted on lans. <br />34 Elect. 5246 Du lex rece tacle does not have a cover 1ate. <br />35 Data/phone Duplex receptacle does not have a cover plate. <br /> 5245 <br />36 Elect. 5246 Panels do not have doors. Circuits are not labeled. <br />37 Recept. 5237 Incomplete installation of door latch backbox on northwest <br /> wall <br />38 Rece t. 5237 Rece tacle on northwest wall not installed. <br />39 Con£ 5208 Incomplete installation of receptacles on south, east and <br /> west walls. <br />40 Rece t. 5237 Incom lete installation of rece tacle behind rece tion desk. <br />41 Computer Incomplete installation of receptacle on west wall. <br /> 5277 <br />We are proceeding with the project based on the above statements being correct. Please notify <br />Interface Engineering, Inc. immediately if there are any corrections or additions to this document. <br />M:\9828\Clerical\Observation Reports~M+E Punch lists\e091200sitevisit.doc Page 2 of 3 <br />