My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Certificate of Substantial Completion
>
CS_Courthouse Square
>
Certificate of Substantial Completion
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2012 4:03:30 PM
Creation date
8/3/2011 4:57:00 PM
Metadata
Fields
Template:
Building
RecordID
10403
Title
Certificate of Substantial Completion
Company
Arbuckle Costic Architects, Inc.
BLDG Date
2/17/1999
Building
Courthouse Square
BLDG Document Type
Project Coordination
Project ID
CS9801 Courthouse Square Construction
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ITE <br />N~ ROOM NO./ <br />LOCATION <br />R'EMAR'KS COMPLETE <br />D <br />24 Provide 0.5 GPM aerator at lavato faucets. <br />25 Missin WCO at water closet wall. <br />26 Breakroom Sink su lies turned OFF. <br />27 3220 Install WH-8. <br />28 Provide dishwasher rou h-in. <br />29 Womens 4133 South L-1 faucet o eratin wild. Ad'ust as re uired. <br />30 North L-1 faucet not o eratin . Ad'ust as re uired. <br />31 Water closet infrared sensors are not operating. Fix <br />roblems. <br />32 Provide 0.5 GPM aerator at lavato faucets. <br />33 Mens 4134 North L-1 faucet not o eratin . Ad'ust as re uired. <br />34 Water closet/urinal infrared sensors are not operating. Fix <br />roblems. <br />35 WCO at L-1 not installed. <br />36 Provide 0.5 GPM aerator at lavato faucets. <br />37 Breakroom <br />4210 Installation not complete at this time. <br />38 Conference <br />4211 Installation not complete at this time. <br />39 Mens 4243 L-1 faucets not o eratin . Ad'ust as re uired. <br />40 Water closet/urinal infrared sensors are not operating. Fix <br />roblems. <br />41 Provide 0.5 GPM aerator at lavato faucets. <br />42 Missin WCO at water closet wall. <br />43 Womens 4254 South L-1 faucet not o eratin . Ad'ust as re uired. <br />44 Water closet infrared sensors are not operating. Fix <br />roblems. <br />45 WCO at L-1 not installed. <br />46 Provide 0.5 GPM aerator at lavato faucets. <br />47 Corridor 4241 EWC-1 not o eratin . <br />48 Janitor 4244 Clean SS-1 to new condition. <br />49 Finish SS-1 installation. <br />We are proceeding with the project based on the above statements being correct. Please notify <br />Interface Engineering, Inc. immediately if there are any corrections or additions to this document. <br />M:\9828\Clerical\Observation Reports~lVl+E Punch lists\p081400sitel.doc Page 2 of 2 <br />