Laserfiche WebLink
10/16/2000 12:02 FA% 50~ 581 ~655 ARBUCRLE COSTIC ~ BILLY WASSON ~002/012 <br />_ _. __. ~ _____~ <br />• ~ , _ __----~ <br />~I NTE RFAC E E GINEERING <br />ConsUltl~p fllQinee s <br />200 Hawthorne Ave, SE #B-210 <br />Saiem, OR 97301 <br />503.364.5354 OFFICE <br />503.364.5434 FAX <br />Project Memorandum <br />SUBJECTiPROJECT: Courthouse Sq Salem TC Revised Design DATE: October 13, 2000 <br />PROJECT NUMBER: 1996-0570.03 ~ROM: Jeff Stauffer <br />TO: Leonard Lodder APPLIES ~ MECHANICAL <br /> Arbuckle Costic Architects, P_C. TO: ~ pLUMBING <br /> 363 State St ^ ELECTRICAI. <br /> Salem, OR 97301-3533 ~ FIRE/LIFE SAFETY <br /> ~ LOW VOLTAGE <br /> F~ ^ LIGHTING <br />PHONE NUMBER: (503) 591-4114 NUMBER: ~503) 581-3655 ~ TELECOM <br />Site Visit Dated 02/24/00 <br />~ 2. ~ Col C/1 a ~ HVAC Contractor provide detail of duct adjustment/depression at drain. f Completed ~ <br />Site Visit Dated 05/09/00 <br />1. 1175 6"m-4 CD-1 off of TU-1-7 is under 26" medium p~essure duct, and ~ex is Completed <br /> crimped. Move diffuser from location to one grid west, and prevent from <br /> crimping. <br />2. 1233 8" 0 spin-in off 36 x 18 from TU-1-10 is bent. Replace before flex Completed <br /> connection is made to LSO. <br />3_ 1201 8" 0 flex not connected to LSD, off of FPB-1-12. Reconnect. Completed <br />4. Roof No cap on flue thru roof at L-12. Attach per 10/M6.1. Completed <br />Site Visit Dated O6/16/00 <br />1. P109, 197, 198, EF~, -7, -5, -3, -6 Installed on spring isolation. Fan inlet connections to Completed <br />209, 298 inlet plenums remaining to be completed. <br />Site Visit Dated 08h 1/00 and 09/14/00 <br />1. Rm. 3231 <br />Waiting Thermostat for Tu-3-16 is not installed_ Install the Thermostat as shown <br />on the drawings. Completed <br />2. Rm. 3134 Location of6x6 CEG-2 and i4x14 CTG-2 are reversed from the Completed <br /> Evidence locations as shown on the plans. DepiCt on as-built drawings in the <br /> installed locations. <br />3. Rm. 3134 Location of Thermostat for TU-3-20 is not as shown on the plans. Depict Completed <br /> Evidence on as-built drawings in the installed location. <br />Site Visit Dated 09H 2/00 <br />1. <br />Vestibule 1235 8' 0 CD~ is broken. Replace. Completed <br />2 24 x 24 CRG-1 not installed. Install grille_ Completed <br />3_ Storage 1234 8" 0 CEG-2 and 12 x 12 CTG-2 are not installed. nstall the grilles. Completed <br />4. Storage 1283 6" 0 CD-1 not installed. lnstall the diffuser. Completed <br />5. Audio Ysual <br />1253 Thermostat for TU-1-8 not installed. Install the thermostat. Completed <br />6~ Assembly 1233 6n ~ CD-6 as installed has incorrect throw. I~stall 2 di sers, 2-way, with <br /> th~ow as depicted. <br />7. Conference <br />1160 Thermostat for TU-1-2 is installed incoRectly. Correct the installation. Completed <br />8. Elevator Lobby <br />1240 Thermostat for TU-1-3 not installed. Install the thermostat. Completed <br />DISTRIBUTION: Page 1 of 2 <br />M:\9828\Clerical\Ob~ervation Reports~lVl+E Punch liste~1VI10130UMemo.DOC <br />