My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Miscellaneous - Arbuckle
>
CS_Courthouse Square
>
Miscellaneous - Arbuckle
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2012 7:05:18 AM
Creation date
8/16/2011 2:38:48 PM
Metadata
Fields
Template:
Building
RecordID
10388
Title
Miscellaneous - Arbuckle
Company
Arbuckle/Costic
BLDG Date
1/1/2000
Building
Courthouse Square
BLDG Document Type
Design - Planning
Project ID
CS9801 Courthouse Square Construction
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NO CHASE GREASE DUCT <br />INSPECTION POINTS <br />The following installation details should be verified to assure a correctly installed NO <br />CHASET"' GREASE DUCT system: <br />1. The pipe must carry the BOCA/SBCCI Label. <br />2. Cleanout access ports are installed in accordance with NFPA 96-1994, Chapter 4. <br />3. The proper sealant (Metal-Fab P/N P080) must be used to seal the joints. <br />4. Supports must be installed in accordance with the support limitations set forth in the <br />instructions and must be fastened securely to the building structure. <br />5. Cleanout access ports are installed so that the built in grease dams are in the correct <br />orientation. <br />6. Grease drains are at the low points of the duct in the area drained and are connected <br />to acceptable grease receptacles. <br />7. Expansion joints are installed in a location such that longitudinal movement is <br />unrestricted by supports or surrounding structure. <br />8. Fan connections must be properly sealed. The duct to fan joint must be sealed with <br />Metal-Fab P/N P080 sealant or gasketed with gasket material in accordance with <br />NFPA 96-1994. <br />9. Any duct penetration of a rated wall must be firestopped in accordance with the <br />installation instructions. <br />METAL-FAB,N <br />~. <br />F <br />MANUFACTURER OF PRODUCTS <br />FOR ENVIRONMENTAL SVSTEMS <br />P. O. BOX 1138 ~ WICHITA, KANSAS 67201 <br />(316) 943-2351 • FAX (316) 943-2717 <br />800-835-2830 <br />~07998 Metal-Fab, Inc. Litho in U SA. <br />Form No. L1508-12/98 <br />
The URL can be used to link to this page
Your browser does not support the video tag.