Laserfiche WebLink
Specialty Analytical <br />Date: 19-May-99 <br />CLIENT: Century West ~;ngineermg QC SUMMARY REPORT <br />Work Order: 9905096 <br /> Continuing Calibration Verification Standard <br />Project: 4080600127/4102 - Courthouse Square <br />Sample ID CCV Batch ID: 1452 Test Code: NWTPH-Dx Units: mg/Kg Analysis Date 5N8/1999 Prep Date SN7/1999 <br />Client ID: 9905096 Run ID: GC-E_990518D SeqNo: 40313 <br />Analyte Resuit PQL SPK value SPK Ref Val %REC LowLimit Highlimit RPD Ref Val %RPD RPOLimit Qual <br />Diesel 993.7 15 999.6 0 99.4% 85 115 <br />Lube Oil 518.2 50 499.6 0 103.7% 85 115 <br />Sample ID CCV Batch ID: 1452 Test Code: NWTPH-Dx Units: mglKg Analysis Date 5H8h999 Prep Date 5H7H999 <br />Client ID: 9905096 Run ID: GC-E_990518 E SeqNo: 40463 <br />Analyte Result PQL SPK value SPK Ref Val %REC LowLimit HighLimit RPD Ref Val %RPD RPDLimit Qual <br />Diesel 939.3 15 999.6 0 94.0% 85 115 <br />Lube Oil 505.1 50 499.6 0 101.1 % 85 115 <br />Sample ID ccv Batch ID: 1457 Test Code: NWTPH-Gx/8 Units: mglKg Analysis Date 5H8l1999 Prep Date 5N711999 <br />Client 10: 9905096 Run ID: GC-H_990518 B SeqNo: 40267 <br />Analyte Result PQL SPK value SPK Ref Val %REC LowLimit HighLimit RPD Ref Val %RPD RPDLimit Qual <br />Benzene 43.02 0.05 50 0 86.0% 85 115 <br />Ethylbenzene 44.73 0.1 50 0 89.5% 85 115 <br />Gasoline 1960 2.5 2000 0 98.0% 85 115 <br />Toluene 44.89 0.1 50 0 89.8% 85 115 <br />Xybnes, Total 135.2 0.3 150 0 90.1 °~ 85 115 <br />~ ~ ~ ~ of~ <br />