Laserfiche WebLink
Septic Permit 555-18-004781-PRMT Page 2 of 3 <br /> s�r c3 cy�'.x-[ y,/ ,� ,�' f��-y3'' � -� t � a -a* ,fie � �,�.°;� a <br /> dt@ t:r Cati� t 0v 044b 4 i k 5 @ k ms 5`��A"'^ `3'V g'd�g <br /> r.: ,�,+, `Sam � � r�s � '�v�' n r,�x aar bi.� -n��, a..3�r'��s��i ��,�" �� � �, <br /> ri <br /> L2rlC 17escripttun4�aR sE s <br /> -a 4 wf IAS <br /> fes, � �" , �`,-;,44,i;:;44- .% ��� �� 5 ,�=� � s b <br /> a <br /> € r 'f s ..''-', �' �a<.'a�' " , ;*`° :. _ a"�,,, lay 4 3r ` '. r .r :24.1 t,6 z` .: <br /> rid�� � '� ��� t �� r.� ✓ri' ����,�-a �>'�' �� � � <br /> ,,, tail-M5•'s iftJi , atsit� G yi v� � is 4� 17 A'3PT�3Y! k .,_ ,,..,i ", ,0Mit ,1*NsEWI`1;-=-I .._._.-. - <br /> Approved Area&System Type <br /> Test pits and other site features were evaluated on June 27,2018. The conditions observed during this site evaluation indicate <br /> that the area around the test pit is capable of supporting a STANDARD system for the REPAIR. Plans are approved as revised. <br /> Please refer to the signed approved site plan dated July 10,2018. Any deviation from the approved plans must be authorized <br /> by this office prior to installation or the permit may be voided. It is the responsibility of applicant/installer to coordinate these <br /> requirements with all others in OAR 340-071-0220. <br /> This Permit is for a system designed to serve a single family dwelling with a maximum of 4 bedrooms. Peak sewage flow into <br /> the system is limited to a maximum of 450 gallons per day,with an average sewage flow of not more than 225 gallons per day. <br /> Premature failure of the treatment system may occur if either of these flow quantities is exceeded. If,for some reason,you <br /> expect your domestic household water use may exceed these flows, it is advisable to increase the size of the treatment system. <br /> Specific Requirements <br /> TANK RISER: The tank must be installed with watertight risers extending to the ground surface or above. The riser lid must be <br /> gasketed and securely fastened. <br /> EFFLUENT SEWER:The effluent sewer is the pipe from the septic tank to the distribution box. The material required is 3034 or <br /> Schedule 40 pipe with 18-gauge minimum green tracer wire or green metallic tape placed along the pipe. The effluent sewer <br /> shall extend at least five(5)feet from the tank. There must be a minimum difference of eight(8)inches between the invert(flow <br /> line)of the septic tank outlet and the invert of the distribution or drop box outlet. In Equal Distribution,there must be six(6) <br /> inches of fall between the septic tank outlet and the distribution box inlet. In Serial Distribution,there must be two(2)inches of <br /> fall between the septic tank outlet and the drop box inlet. <br /> HEADER PIPE between Distribution Box and drainfleld trench must measure a minimum of 4 feet, must be installed level,and <br /> bedded on undisturbed earth. <br /> OBSERVE ALL SETBACKS AND SEPARATION DISTANCES as required by the Department of Environmental Quality rules. A <br /> copy of the DEQ setback requirements is available in our office and online at - <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx under Rules: Division 71:Table 1. <br /> THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any vehicular traffic, livestock and farming activities. <br /> Other activities such as excavating or filling,driveway placement, paving or other similar activities that alter the natural soil <br /> conditions will adversely affect the soil and the septic system function and lead to premature system failure. The area must not <br /> be subjected to excessive saturation due to artificial drainage of ground surfaces,driveways, building downspouts or other <br /> sources. The areas of the initial septic system and the future repair system must both be protected. <br /> MAINTAIN PERMANENT ACCESS to septic tank for pumping and service.The septic tank should be pumped and inspected by <br /> a licensed septic tank pumping service before sludge and scum accumulations reach 30%of the tank liquid operating volume. <br /> Pumping every 3 to 5 years is an average interval. The septic tank is a reservoir for the solid materials in the sewage waste <br /> stream. Excessive accumulation of these solid materials in the septic tank will cause the solids to wash out of the tank and into <br /> the drainfield. This will cause irreversible damage to the drainfield and will eventually lead to a system failure. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure. Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely <br /> affect the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling, cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the <br /> issuance of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices, alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including <br /> payment of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> 3/28/19:3:08:57PM Page 2 of 3 ONS_OnsiteCSC_pr <br />