My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8573867
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
19-XXXXXX
>
8573867
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2019 9:36:13 AM
Creation date
4/1/2019 9:18:56 AM
Metadata
Fields
Template:
Permits
Permit Address
12255 BUDLONG LN SE
Permit City
MILL CITY
Permit Number
555-19-002101-EVAL
Parcel Number
092E24 00600
Permit Type
Site Evaluation
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Oregon Department of Environmental Quality <br /> • Dosing tank capacity (gallons) <br /> • Tank volume determined by:Check all that apply,add comments below as needed <br /> ❑Permit Records 0 Measured❑Stamped on Tank 0 Other <br /> • Dosing tank material <br /> • Dosing tank appears to be watertight and in good condition ['Yes ❑No <br /> • Dosing tank lid is intact ❑Yes ONo <br /> • Electrical components are sealed and watertight Dyes ❑No <br /> • Pump/siphon is functional ['Yes ONo <br /> • Type of Pump ['Demand dose ['Time dose <br /> • Pump control mechanism is functional(floats,pressure transducer)['Yes ONo <br /> • There is a high water alarm❑Yes ONo <br /> • The high water alarm(audible and visual)is working ['Yes ONo ['Not Applicable <br /> • 'Type of screen <br /> • Screen is clean and free of debris Dyes ❑No-Screen cleaned for this evaluation['Yes ❑No <br /> • Scum/sludge present in Dosing tank ['Yes ['No <br /> • Scum layer (inches) Sludge layer (inches) <br /> • Additional Comments: <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> • The septic system has a soil absorption system ZYes ['No ['Unknown <br /> • Was the soil absorption system part of the evaluation?®Yes ONo ['See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to <br /> locate,client did not authorize this part of the evaluation): <br /> • Absorption distribution DEqual ®Serial ['Pressure ['Equal via pressure <br /> • Absorption lines construction material: <br /> ❑Gravel and pipe 21 Chamber ❑Tile 0 Polystyrene foam and pipe ['Other <br /> • Absorption distribution unit(s):®dropbox❑hydrosplitter['equal distribution box <br /> ❑Intact 0 Damaged ❑N/A <br /> • Absorption distribution unit(s)are free of debris or solids Dyes ONo 0 N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.