My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8576246
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
18-XXXXXX
>
8576246
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2019 8:49:46 AM
Creation date
4/3/2019 10:57:45 AM
Metadata
Fields
Template:
Permits
Permit Address
10052 ENCHANTED WAY SE
Permit City
JEFFERSON
Permit Number
555-18-003782-PRMT
Parcel Number
093W02 00500
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONSOLIDATED CONTROL PANEL (SURGE DOSING TANK AND FAST TANK) CUSTOM MVP <br />Pump Selection for a Non -Pressurized System - Commerical Project REQUIRED OPTIONS <br />St. Innocent Winery / Surge Tank to Treatment Unit(PF100511 FC) <br />QUANTITY DESCRIPTION <br />Parameters 2 ELAPSED TIME METERS: <br />DischargeAssemblySi2n <br />1.OFC <br />inches <br />COUNTERS: <br />Transport Length <br />24 <br />feet <br />HORIZONTAL BASE MOUNT <br />Transport Pipe Class <br />40 <br />3 <br />CURRENTSENSOR <br />Transport Line Size <br />1.00 <br />inches <br />ALARM LIGHT- PUMP/BLOWER FAIL <br />Distributing VaMeModel <br />None <br />1 <br />ALARM LIGHT -NIGH LEVEL ALARM <br />Max Elevation Lift <br />2.5 <br />feet <br />INDICATOR LIGHT- HIGH LEVEL OVERRIDE TIMER <br />Design Flow Rate <br />10 <br />gpm <br />ALARM LIGHT- LOW LEVEL ALARM <br />Row Meter <br />None <br />inches <br />ADDITIONAL COUNTER <br />"Add-on'Friction Losses <br />0 <br />feet <br />GENERAL ALARM DRY CONTACT <br />Calculations <br />(REMOTE ALARM RELAY) <br />1 <br />PANEL HEATER (100 WATT) WITH ADJUSTABLE THERMOSTAT , <br />Transport Velocity <br />3.7 <br />fps <br />Minimum of 1 Cycle (Complete Each Cycle -ON Time -Regardless of Float Position) <br />Timer Settings: <br />1 minute ON (10 gallons per dose) <br />m <br />Frictional Head Losses <br />li <br />Loss through Discharge <br />75.0 <br />feet <br />_ <br />a <br />Loss in Transport <br />1.3 <br />feet <br />F <br />Lossthrough Valve <br />0.0 <br />feet <br />Loss through Flowmeter <br />0.0 <br />feet <br />'Add-on'Friction Losses <br />0.0 <br />feet <br />V <br />E <br />Pipe Volumes <br />a <br />Vol of Transport Line <br />1.1 <br />.gals <br />m <br />t° <br />Minimum Pump Requirements <br />Design Flow Rate <br />10.0 <br />gpm <br />Total Dynamic Head <br />- 78.8 <br />feet <br />_0 5 10 15 <br />Net Discharge (gpm) Nigh Level Override Timer Function -Alternating Cycles at Increased Frequency <br />Minimum of 1 Cycle (Complete Each Cycle - ON Time - Regardless of Float Position) <br />Timer Settings- 1 minute ON (10 gallons per dose) <br />PumoData 9 minutes, 40 seconds OFF <br />PF1005High Head Effluent Pump <br />10 GPM, 1/2HP <br />11 5123D 106CHz20OV 3060Hz <br />PF1007 High Head Effluent Pump <br />10 GPM,314HP <br />230V 106OH7, 200V 30 60H <br />PF1010 High Head Effluent Pump <br />10 GPM, 1 HP <br />230V 1060Hz, 200V 30 60H <br />Minimum Power Requirements at Panel <br />115 VAC, Single Phase, 60 Hertz <br />2 @ 20 AMP (1 for each Pump) <br />1 @ 20 AMP (FAST Blower Controller) <br />1 @ 10 AMP (115 VAC for Panel) <br />1 @ 10 AMP (115 VAC for Heater) <br />40 AMP Service, 115 VAC (L1, N, G), Single Phase (Minimum) from Power Source (Pumps, Blower) <br />20 AMP Service 115 VAC (L1 N G) Single Phase (Minimum) from Power Source (Controls, Heater) <br />115 VAC, 7 -DIGIT, NONRESETTABLE <br />2 <br />COUNTERS: <br />REFERENCE: ORENCO QUOTE NUMBER 042318TS1 <br />115 VAC, 6 -DIGIT, NONRESETTABLE <br />HORIZONTAL BASE MOUNT <br />2 <br />PUMP RUN LIGHTS <br />3 <br />CURRENTSENSOR <br />(1 FOR EACH PUMP + BLOWER) <br />3 <br />ALARM LIGHT- PUMP/BLOWER FAIL <br />12.7 running amps at 115 VAC <br />(BLUE WITH LABEL) <br />1 <br />ALARM LIGHT -NIGH LEVEL ALARM <br />(RED WITH LABEL) <br />1 <br />INDICATOR LIGHT- HIGH LEVEL OVERRIDE TIMER <br />(AMBER WITH LABEL - NO AUDIBLE) <br />1 <br />ALARM LIGHT- LOW LEVEL ALARM <br />Redundant Off/Low LewAlarm <br />(RED WITH LABEL) <br />1 <br />ADDITIONAL COUNTER <br />YT). F1RWyR1:W F,p. <br />FOR "HIGH LEVEL OVERRIDE" FLOAT <br />1 <br />GENERAL ALARM DRY CONTACT <br />(REMOTE ALARM RELAY) <br />1 <br />PANEL HEATER (100 WATT) WITH ADJUSTABLE THERMOSTAT , <br />1 <br />SURGE ARRESTOR <br />Normal Timer Function -Alternating Cycles <br />Minimum of 1 Cycle (Complete Each Cycle -ON Time -Regardless of Float Position) <br />Timer Settings: <br />1 minute ON (10 gallons per dose) <br />20 minutes, 20 seconds OFF <br />_0 5 10 15 <br />Net Discharge (gpm) Nigh Level Override Timer Function -Alternating Cycles at Increased Frequency <br />Minimum of 1 Cycle (Complete Each Cycle - ON Time - Regardless of Float Position) <br />Timer Settings- 1 minute ON (10 gallons per dose) <br />PumoData 9 minutes, 40 seconds OFF <br />PF1005High Head Effluent Pump <br />10 GPM, 1/2HP <br />11 5123D 106CHz20OV 3060Hz <br />PF1007 High Head Effluent Pump <br />10 GPM,314HP <br />230V 106OH7, 200V 30 60H <br />PF1010 High Head Effluent Pump <br />10 GPM, 1 HP <br />230V 1060Hz, 200V 30 60H <br />Minimum Power Requirements at Panel <br />115 VAC, Single Phase, 60 Hertz <br />2 @ 20 AMP (1 for each Pump) <br />1 @ 20 AMP (FAST Blower Controller) <br />1 @ 10 AMP (115 VAC for Panel) <br />1 @ 10 AMP (115 VAC for Heater) <br />40 AMP Service, 115 VAC (L1, N, G), Single Phase (Minimum) from Power Source (Pumps, Blower) <br />20 AMP Service 115 VAC (L1 N G) Single Phase (Minimum) from Power Source (Controls, Heater) <br />St. Innocent Winery <br />10052 Enchanted Way SE <br />Jefferson, OR <br />REV # DESCRIPTION BY DATE <br />DES. BY tern <br />DRG. BY 6ruR <br />CHK. BY 1GLT00 <br />DATE 4/26/2018 <br />JOB No. P201824042 <br />4000 <br />REFERENCE: ORENCO QUOTE NUMBER 042318TS1 <br />- SHEET <br />Pump Curve and Control Panel Data <br />C 1 <br />Sewage Treatment System <br />Orento Systema`:. <br />PF 100511 FC <br />u D-` <br />12.7 running amps at 115 VAC <br />5^ <br />Four Floats High Leel Alarm <br />High Leeel Override Timer <br />Normal Timer ON/OFF <br />C- is�a P�f—i. <br />sons. -a <br />Redundant Off/Low LewAlarm <br />a>�vE�p. <br />YT). F1RWyR1:W F,p. <br />REUSE OF DOCUMENTS: THIS DOCUMENT AND THE IDEAS AND DESIGN INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE IS THE PROPERTY OF CASCADE EARTH: SCIENCES AND IS NOT TO BE USED, WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION OF CASCADE EARTH SCIENCES <br />St. Innocent Winery <br />10052 Enchanted Way SE <br />Jefferson, OR <br />REV # DESCRIPTION BY DATE <br />DES. BY tern <br />DRG. BY 6ruR <br />CHK. BY 1GLT00 <br />DATE 4/26/2018 <br />JOB No. P201824042 <br />4000 <br />- <br />CES CASCADE EARTH SCIENCES <br />- SHEET <br />Pump Curve and Control Panel Data <br />C 1 <br />Sewage Treatment System <br />
The URL can be used to link to this page
Your browser does not support the video tag.