Permit Address
10574 MILL CREEK RD SE
Permit City
AUMSVILLE
Permit Number
555-19-003012-AUTH
Parcel Number
081W32B 01600
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> * Dosing tank capacity (gallons) <br /> * Tank volume determined by:Check all that apply,add comments below as needed. <br /> 1 Permit Records Measured Stamped on Tank Other <br /> * Dosing tank material <br /> * Dosing tank appears to be watertight and in good condition Yes No <br /> * Dosing tank lid is intact YesNo <br /> * Electrical components are sealed and watertight Yes No <br /> * Pump/siphon is functional Yes !No <br /> * Type of Pump Demand dose Time dose <br /> * Pump control mechanism is functional(floats,pressure transducer) Yes No <br /> * There is a high water alarm ;Yes I No <br /> * The high water alarm(audible and visual)is working Yes NoNot Applicable <br /> * Type of screen <br /> * Screen is clean and free of debris Yes iNo <br /> * Screen cleaned for this evaluation Yes No <br /> * Scum/sludge present in Dosing tank � Yes 1 No <br /> * Scum layer (inches) Sludge layer (inches) <br /> * Additional Comments: <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> * The septic system has a soil absorption system x Yes `No Unknown <br /> * Was the soil absorption system part of the evaluation? x Yes No , See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to locate,client did not <br /> authorize this part of the evaluation): <br /> * Absorption distribution x Equal ;Serial Pressure 'Equal via pressure <br /> * Absorption lines construction material: <br /> x Gravel and pipe Chamber Tile Polystyrene foam and pipe Other <br /> * Absorption distribution unit(s): dropbox hydrosplitter x equal distribution box <br /> x •Intact Damaged N/A <br /> * Absorption distribution unit(s)are free of debris or solids Yes No N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.