8675311
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
19-XXXXXX
>
8675311
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2019 8:43:57 AM
Creation date
6/20/2019 2:27:07 PM
Metadata
Fields
Template:
Permits
Permit Address
5925 STATE ST
Permit City
SALEM
Permit Number
555-19-003587-AUTH
Parcel Number
072W28C 02300
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> z f <br /> Oregon Department of Environmental Quality <br /> • The septic tank material is: <br /> I Concrete <br /> ❑ Steel <br /> Plastic <br /> ❑ Fiberglass <br /> ❑ Other(explain) <br /> ® Unknown <br /> • Is the septic tank accessible? ®Yes ❑No <br /> • Septic tank volume in gallons 1,000 <br /> • Tank volume determined by: Check all that apply,add comments below as needed <br /> ®Permit Records®Measured❑Stamped on Tank Other <br /> • Septic tank risers are at ground level <br /> Yes ❑No <br /> • Tank appears to be free from defects,leaking and signs of deterioration®Yes ONo <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> • Septic tank lid(s)is intact ®Yes ❑No <br /> • Septic tank baffles are intact: Inlet ®Yes ❑No Outlet ®Yes ❑No <br /> • Baffle material-Inlet[Plastic OConcrete EMetal Outlet k Plastic OConcrete EMetal <br /> Effluent filter is present ❑Yes ENo <br /> • Effluent filter is free of debris DYes ❑No Not Applicable <br /> • Liquid level in tank relative to invert of outlet At ❑Above ❑Below <br /> If above or below invert outlet,please explain: <br /> • Scum layer 1 (inches) Sludge layer 6 (inches) <br /> • Scum and Sludge layer more than 35% of the total tank volume DYes E]No <br /> Indicate where sludge measured from: ❑Inlet ❑Middle DOutlet <br /> • Additional Comments: <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or a soil ab•orption field. <br /> • The septic system has a dosing tank DYes ONo <br /> (If"No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s): D -s ❑No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.