My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11991311
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
11991311
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 12:32:19 PM
Creation date
12/26/2023 2:22:10 PM
Metadata
Fields
Template:
Permits
Permit Address
5915 WINDSOR ISLAND RD N
Permit City
Keizer
Permit Number
555-21-000812-ELEC
Parcel Number
063W33 00200
Permit Type
Electrical
Extra Information
2021 Master Permit
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FAN01 IEXH01 RBL 8/19/20 00414CFB1 CENTRIFUGE CONTROL ROOM IS VERY HOT.98 DEG F <br /> VENTILATION DOES NOT SEEM TO BE WORKING...Replaced <br /> thermostat.Copper wiring and refrigeration piping is black and <br /> flaking...Replaced Bard heat pump with mini split heat pump. <br /> 012 THICKENER FACILITY <br /> ITEM BY C-DATE W/O# • <br /> MOT012DAFT02 BJL 11/12/20 01110KJWI PUMP WILL NOT RESET VIA DCS---Adjusted overloads to the <br /> correct setting. <br /> MOTOI2DAFT03 BJL 11/12/20 01110KJW2 LOCAL PANEL WILL NOT RESET. DCS ALARM SAYS <br /> RECYCLE PUMP#3 OVERLOAD---Reset overloads and adjusted <br /> to the correct setting <br /> 016 GRIT FACILITY(OLD RAW PS) <br /> ITEM BY C-DATE W/O# <br /> 001FCV011A BJL 4/20/20 91125LLG1 THE OLD GATE OPERATOR FAILED. INSTALL A NEW <br /> ROTORK.---Wired in new gate. <br /> 001 FCV012A MJN 5/27/20 00507MJN 1 CHANNEL GASES HAVE CORRODED FITTINGS AND THEY <br /> NEED TO BE REPLACED. REPLACE WITH NEW OCAL <br /> COATED FITTINGS AFTER MECHANICS HAVE MODIFIED <br /> GUARDS.----Work completed by NSE <br /> 016 MJN 10/23/20 00525MJN 1 MOVE DCS OUTSIDE ALARM BELL AND STROBE TO THE <br /> TOP OF THE GRIT CLASSIFIER ROOF. <br /> work completed by NSE <br /> 019 S PRIMARY TREATMENT FACILITY <br /> ITEM BY C-DATE W/O# <br /> 019 EC 2/6/20 00122BDW1 REPLACE SPE ELECTRICAL ROOM T8 LAMPS WITH LED <br /> TUBES.---Rewired light fixtures for LED tubes.removed ballast and • <br /> relamped fixtures. <br /> EDP-LC MJN 9/15/20 00618MJN3 ELECTRICAL TESTING BY VERTIV INDICATES THAT <br /> NEUTRALS AND GROUND WIRES ARE TERMINATED ON <br /> THE GROUND BAR.NEED TO INVESTIGATE AND MAKE <br /> NECESSARY CORRECTIONS---The only neutral on the gound bar <br /> is the required main abonding jumper. <br /> FIT-104 PJS 2/27/20 91116WJM1 DCS INDICATES SOUTH ST FLOW ON 11-15-19 AT 22:21:36. <br /> LOCAL METER STARTING TO SHOW MORE ERRORS. PUMPS <br /> ARE NOT RUNNING TO GENERATE FLOW. Seems the new <br /> ST-H probe is more sensitive to fog issues than the old ST-25 probe. <br /> Replaced the ST-H ultrasonic probe with an E+H FMR20 radar <br /> sensor/tranmitter wired to the mA input on the Milltronics <br /> HydroRanger 200 ultrasonic transmitter.The FMR20 output is <br /> configured in feet of flume-head level whereas the HydroRanger 200 <br /> input signal is configured in 0 to 100%and the output is configured in <br /> MGD linearized flow,with totalizer. So far no issues,even with heavy <br /> fog outside. <br /> LCV-103 PJS 1/9/20 00109FJSI PLEASE REPAIR AIR LEAK.ALSO SPEED UP CONTROLLER <br /> RESPONSE. <br /> The Fisher Fieldvue DVC6000 series pneumatic controllers are <br /> continuous bleed controllers(throddling controllers)and will <br /> consume air even when at steady-state conditions. With the supply air <br /> of 41 psig using a standard pneumatic relay the steady-state air <br /> consumption is about 27 SCFH. LCV-103 is acting normally.The <br /> response of the controller is tuned for the wet well recycle valve • <br /> application. <br /> ' Page 8 of 20 <br />