• <br /> 101 FCV081 A BJL 8/26/20 00819GCP2 NEW BY-PASS GATE HAS BEEN INSTALLED.NEED TO <br /> MAKE MODIFICATIONS SO NEW POSITION PROXIMITY <br /> SWITCH'S WORK WITH EXISTING PANEL.---shortened conduit <br /> • <br /> and rewired sensor on new gate. <br /> • 101 FCV082A BJL 8/26/20 00819GCP3 NEW BY-PASS GATE HAS BEEN INSTALLED.NEED TO <br /> MAKE MODIFICATIONS SO NEW POSITION PROXIMITY <br /> SWITCH'S WORK WITH EXISTING PANEL.---shortened conduit, <br /> rewired sensor on new gate. <br /> ELTIOIL BJL 3/9/20 00218BJL2 EMERGENCY LIGHT FAILED 30 MINUTE TEST.NEW J CELL <br /> BATTERY ASSEMBLY IS ON ORDER.---according to battery <br /> supplier,J cell battery is no longer available.replaced batter with a <br /> single 12 volt DC 12 Ah battery.working ok. <br /> HWHIOIHW01 MJN 8/18/20 00814JGM1 BAR SCREEN WATER HEATER IS NOT HEATING WATER. <br /> TEMP IS AT 70 DEG---Manual over temp switch was tripped.reset <br /> switch,working ok. <br /> PNL I O 1 M BJL 1/31/20 00102GCP2 PLEASE ADD RUN INDICATION FOR THE HYDRAULIC <br /> PUMP.----installed run light and updated prints <br /> PNLI OI M BJL 2/24/20 00219KJW1 THE LOCAL TRIDENT GATE#1 CONTROL PANEL IS <br /> DISPLAYING THAT IT IS IN THE OPEN AND CLOSED <br /> POSITION AT THE SAME TIME.---If gate is not 100%open or <br /> closed both open and closed lights will be lit. During closing,open <br /> light will be lit and closing light will flash. During opening,close light <br /> will be lit and open light will flash.At 100%open,only open light <br /> will be lit.At 100%closed,only closed light will be lit. <br /> PNLIOIN BJL 1/31/20 00102GCP3 PLEASE ADD RUN INDICATION FOR THE HYDRAULIC <br /> PUMP.----installed run light and updated prints <br /> PNLIOIN MJN 5/5/20 00504DER1 THE GATE WILL NOT CLOSE.---Replaced blown A-Phase fuse. <br /> • <br /> PNLI Ol T BJL 1/27/20 91104JLC1 HEAT TRAACE FAILED AFTER BEING RESET---Replaced both <br /> sensing boards and calibrat boards. <br /> SMPIOIRAW01 RBL 9/17/20 00916WJM1 TEMP HAS BEEN RISING DAYLY. PLEASE ADJUST,FIX OR <br /> WHATEVER TO MAINTAIN DEQ STANDARDS... Defrosted <br /> evaporator and removed blue ice from refrigerator. <br /> 104 INFLUENT PUMP STATION <br /> ITEM BY C-DATE W/O# <br /> 104 MJN 1/21/20 90918FJS1 PLEASE EXTEND LIGHTING CIRCUIT AND CONDUIT TO <br /> INSTALL A 4'WET LOCATION LED FIXTURE ABOVE THE IPS <br /> PH SAMPLE BOX.---work completed by NSE <br /> 104AIT502A CLC 10/7/20 00824AJA1 INPUT BAD ALARM ON DCS---replaced faulty sensor and <br /> ordered replacement <br /> 104FIT117A CLC 10/13/20 00519CLC1 FLOW METER SHOWS FLOW SPIKES AFTER PUMP HAS <br /> SHUT DOWN---problem has not re-occured <br /> VFD104RS06 BJL 2/24/20 00203BRB1 PUMP FAILED.TRIED TO RESET,COULDN'T GET IT BACK <br /> ON-LINE.CAN GET TO RUN BUT PUMP FAIL LIGHT WILL <br /> NOT CLEAR.---monitored temperatures for three weeks.alaram <br /> didn't come back in/ <br /> 105 HEADWORKS ELECTRICAL FACILITY <br /> • ITEM BY C-DATE W/O# <br /> 105 MJN 10/23/20 00610BDW2 ORDER AND INSTALL LED LAMPS IN IPS BASEMENT <br /> FIXTURES. <br /> Work completed by NSE <br /> Page 17 of 20 <br />