Laserfiche WebLink
• <br /> SMP 1 16NFE01 PJS 11/19/20 01119DJB1 SAMPLER PINCH VALVE SIEZED UP. HAD TO PRY ON IT TO <br /> GET IT TO WORK. DOSEN'T SOUND RIGHT WHEN CYCLING <br /> DURING SAMPLING. Replaced pinch valve.Tested. Works fine <br /> now. <br /> SMP116SFE01 RBL 5/21/20 00521DER1 The SFE sampler pinch hose has a hole in it...Replaced hose. • <br /> SMP116SFE01 CLC 7/1/20 00624CLC2 PROVIDE VENTILATION TO SAMPLER ENCLOSURE---vents <br /> installed <br /> SMP116SFE01 RBL 8/5/20 00803LLG2 FRIDGE IS NOT ACHIEVING TEMPERATURE <br /> SETPOINT...Defrosted evaporator. <br /> SMP116SFE01 RBL 8/18/20 00817LLG1 UNIT NOT MAINTAINING SETPOINT.CONTROLLER IS <br /> READING 2 DEG.TRACEABLE IS 8 DEG WITH BLUE ICE <br /> PACKS...Blue ice packs too close to controller sensor will satisfy <br /> controller setpoint and stop cooling refrigerator. <br /> UPS 116A BJL 7/28/20 00629MJN 1 REPLACED OBSOLETE UPS AS A PREVENTITIVE MEASURE <br /> BEFORE IT FAILS.---Replaced UPS and updated prints. <br /> 117 PRIMARY SWITCH GEAR <br /> ITEM BY C-DATE W/O# <br /> 117 MJN 8/21/20 00807EC01 FALSE FIRE ALARM FROM SWITCHGEAR BUILDING 117, <br /> PHOTO SMOKE DETECTOR D32.----REPLACE SMOKE <br /> DETECTOR AND RESET SYSTEM. <br /> • <br /> • <br /> Page 20 of 20 <br />