005 PROCESS SUPPORT FACILITY <br /> ITEM BY C-DATE W/O# <br /> 005 EC 1/21/20 91205EC01 LIGHT ABOVE BACK DOOR TO COURT YARD IN REAGENT <br /> AREA OF LAB. ONLY ONE LAMP IS WORKING AFTER <br /> REPLACING BALLAST. MAY NEED NEW TOMB • <br /> STONES---replaced tomb stones. <br /> 005 MJN 10/14/20 91201BDW1 INSTALL WIRING AND TERMINATIONS FOR ADDITIONAL <br /> WIRELESS ACCESS POINTS IN VARIOUS LOCATIONS <br /> THROUGHOUT PLANT TO BE DETERMINED...Completed <br /> 005 DVS 1/8/20 00106DVS1 CARD READER ON LAB RIO/DI ROOM DOOR HAS FAILED. <br /> ---Replaced card reader,was not the problem. Replaced 1300 <br /> processor card,solved issue. <br /> 005 EC 2/6/20 00128CSM 1 SWITCH FOR THE LIGHT IN THE BOD INCUBATOR IS <br /> BROKE.---Installed new pilot light switch. <br /> 005 MJN 3/31/20 00302MJN1 OUTER ADA DOOR BETWEEN PSF AND MAINT SHOP WILL <br /> NOT OPEN WHEN BUTTON IS PUSHED.TROUBLESHOOTING <br /> FOUND THAT THE CLUTCH FOR THE ACTUATOR IS <br /> SLIPPING AND NOT CONSISTANTLY OPENING THE <br /> DOOR.---Service tech replaced clutch for door opener. <br /> 005 MJN 8/1/20 00716BDW1 KEIZER FIRE DISTRICT INSPECTIONS REVEALED THE <br /> FOLLOWING VIOLATION.605.1 ABATEMENT OF <br /> ELECTRICAL HAZARDS: DISCONTINUE USE OF(two wire) <br /> TIMER WITH GROUND REMOVER AT COFFEE POT IN <br /> MAINTENANCE BREAK ROOM. <br /> New three wire, 1800 watt timer installed <br /> 005 MJN 8/1/20 00716BDW5 KEIZER FIRE DISTRICT INSPECTIONS REVEALED THE <br /> FOLLOWING VIOLATION.605.10.1 LISTED AND LABELED: • <br /> DISCONTINUE USE OF SPACE HEATER WITHOUT TIP OVER <br /> PROTECTION. <br /> Heater has been removed from the plant site. <br /> 005 BJL 9/30/20 00928RAC1 REPLACE TOMBSTONES, BALLASTS AND LAMPS IN <br /> RANDY'S OFFICE THAT WHERE REMOVED WHEN <br /> STEPHANE HAD THE OFFICE.---Installed socket and replaced <br /> tubes <br /> 005 BJL 11/24/20 0111OBJLI REMOVE FAILED AND ABANDONED DOOR POWER SUPPLY <br /> AND ASSOCIATED WIRING FROM CEILING IN LUNCH <br /> ROOM.---Removed power wires to power supply and removed circuit <br /> board from J-box above ceiling tiles N.E.of double doors by lunch <br /> room. Removed signal wires back to communications room. <br /> AED005A DVS 3/13/20 00216JLC1 PADS HAVE EXPIRED.---Replaced pads. Expiration Date: 6/2022 <br /> AED005A GCP 7/9/20 00703JLC1 ALARMING ON LOW BATTERY.---Replaced battery. <br /> BLR005HW01 RBL 8/19/20 00410RBL1 BOILER IS TRIPPING OFF LINE...Found boiler return water was <br /> being divided between online and offline boilers.Online boiler was <br /> tripping on high temp alarms due to low water flow...Had AERCO <br /> boiler water isolation valves installed.Tested ok. <br /> CH005CW01 RBL 8/19/20 00508RBL1 COMPRESSOR#1 NOT RUNNING. PLC ALARM "STARTER <br /> FAULT Cl"...Opened main chiller breaker and measured resistance <br /> across SCR's. Found L3 SCR resistance read almost four times as • <br /> high. Restored power. Both compressors are now running...Swapped <br /> starters CI to C2,and problem followed to C2...Ordered and replaced <br /> CI starter. <br /> Page 4 of 20 <br />