004FSLOI OA BJL 8/6/20 00803BNW4 COMPRESSOR DOES NOT SHUT OFF WHEN SEAL WATER IS <br /> TURNED OFF----Flow switch worked when tested. <br /> 004LT170A RBL 7/21/20 00721JPOI Cleaned South Loading Dock level transmitter. <br /> • AI-1001 RBL 12/8/20 01021PJS2 FYRITE HAS A LEAKING DIAPHRAM AND IS LOW IN FLUID. <br /> THE I&E DEPARTMENT WILL NOW BE IN CHARGE OF THE <br /> MAINTENANCE OF THE FYRITES. <br /> AI-1001 PJS 12/8/20 01207PJS1 FLUID LEVEL IS LOW,CANNOT ZERO.No visible leaks.Added <br /> FYRITE fluid. Re-zeroed. <br /> CMP-0006 BJL 8/6/20 00803BNW2 SEAL WATER STAYS ON WHEN COMPRESSOR IS TURNED <br /> OFF--Cleaned out solinoid body. <br /> CMP-0011 BJL 8/6/20 00803BNW I SEAL WATER STAYS ON WHEN COMPRESSOR IS TURNED <br /> OFF---Cleaned solinoid body <br /> ELT0403 MJN 3/5/20 00218BJL3 EMERGENCY LIGHT FAILED 30 MINUTE TEST.NEW <br /> 4.8V/700mAH BATTERY IS ON ORDER.----Replaced battery <br /> FCV-107B BJL 3/23/20 00322SRA1 POSITION INDICATOR DOES NOT WORK CAUSING A FAIL <br /> SIGNAL.---Replaced limit switch. <br /> FCV-107B BJL 5/5/20 00502DJB1 FEED VALVE SEEMS SLOW TO RESPOND TO OPEN <br /> COMMANDS.THIS CAUSES A FAIL TO OPEN ALARM ON <br /> DCS. MECHANICS THINK THE SOLINOID IS LEAKING BY SO <br /> REPLACE SOLIDOID.---Replaced solinoid <br /> FCV-107D EC 7/22/20 00719KJW1 WHEN THE VALVE IS ON THE OPEN POSITION THE <br /> • SOLENOID IS LEAKING LOTS OF AIR---Replaced and tested <br /> solinoid. <br /> PSP-0029 MJN 12/28/20 01215MJNI WEST SUMP PUMP IS RUNNING ALL THE TIME.---Replaced <br /> float switch. <br /> TI-157 PJS 11/6/20 01 105BGW 1 TEMP SHOWN JUMPING AROUND BETWEEN 99.3 AND 99.5 <br /> AT A CONSTANT PACE. Left PC mounted multiturn potentiometer <br /> behind faceplate has an oxidized point of contact between wiper and <br /> trace. Wiping the pot does not fix the problem. Moved point of <br /> contact away from oxidized point.Now OK. DCS reading 99.1 Deg F <br /> and Red Lion APLCL401 indicator reading 99.0 Deg F. <br /> T1-157 PJS 12/1/20 01123BGW1 THE READOUT IS JUMPING OUT A LOT. Issue happened again. <br /> Replaced indicator with a used unit.Now OK. <br /> See W/O 01105BGW 1:TEMP SHOWN JUMPING AROUND <br /> BETWEEN 99.3 AND 99.5 AT A CONSTANT PACE. Left PC <br /> mounted multiturn potentiometer behind faceplate has an oxidized <br /> point of contact between wiper and trace. Wiping the pot does not fix <br /> the problem. Moved point of contact away from oxidized point.Now <br /> OK. DCS reading 99.1 Deg F and Red Lion APLCL401 indicator <br /> reading 99.0 Deg F. <br /> VFD004DS02 MJN 1/24/20 00121JMG1 THE"0" KEY ON THE HIM IS NOT WORKING.---Replaced <br /> keypad.all ok. <br /> VFD004DS03 MJN 5/11/20 00509JMG 1 THE"0" KEY ON CONTROL PANEL IS NOT <br /> • WORKING.---Replaced keypad. <br /> VFD004DSO4 MJN 8/18/20 00815KJW 1 NO POWER TO VFD---Reset breaker in VFD panel <br /> Page 3 of 20 <br />