My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11991311
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
11991311
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 12:32:19 PM
Creation date
12/26/2023 2:22:10 PM
Metadata
Fields
Template:
Permits
Permit Address
5915 WINDSOR ISLAND RD N
Permit City
Keizer
Permit Number
555-21-000812-ELEC
Parcel Number
063W33 00200
Permit Type
Electrical
Extra Information
2021 Master Permit
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
004FSLOI OA BJL 8/6/20 00803BNW4 COMPRESSOR DOES NOT SHUT OFF WHEN SEAL WATER IS <br /> TURNED OFF----Flow switch worked when tested. <br /> 004LT170A RBL 7/21/20 00721JPOI Cleaned South Loading Dock level transmitter. <br /> • AI-1001 RBL 12/8/20 01021PJS2 FYRITE HAS A LEAKING DIAPHRAM AND IS LOW IN FLUID. <br /> THE I&E DEPARTMENT WILL NOW BE IN CHARGE OF THE <br /> MAINTENANCE OF THE FYRITES. <br /> AI-1001 PJS 12/8/20 01207PJS1 FLUID LEVEL IS LOW,CANNOT ZERO.No visible leaks.Added <br /> FYRITE fluid. Re-zeroed. <br /> CMP-0006 BJL 8/6/20 00803BNW2 SEAL WATER STAYS ON WHEN COMPRESSOR IS TURNED <br /> OFF--Cleaned out solinoid body. <br /> CMP-0011 BJL 8/6/20 00803BNW I SEAL WATER STAYS ON WHEN COMPRESSOR IS TURNED <br /> OFF---Cleaned solinoid body <br /> ELT0403 MJN 3/5/20 00218BJL3 EMERGENCY LIGHT FAILED 30 MINUTE TEST.NEW <br /> 4.8V/700mAH BATTERY IS ON ORDER.----Replaced battery <br /> FCV-107B BJL 3/23/20 00322SRA1 POSITION INDICATOR DOES NOT WORK CAUSING A FAIL <br /> SIGNAL.---Replaced limit switch. <br /> FCV-107B BJL 5/5/20 00502DJB1 FEED VALVE SEEMS SLOW TO RESPOND TO OPEN <br /> COMMANDS.THIS CAUSES A FAIL TO OPEN ALARM ON <br /> DCS. MECHANICS THINK THE SOLINOID IS LEAKING BY SO <br /> REPLACE SOLIDOID.---Replaced solinoid <br /> FCV-107D EC 7/22/20 00719KJW1 WHEN THE VALVE IS ON THE OPEN POSITION THE <br /> • SOLENOID IS LEAKING LOTS OF AIR---Replaced and tested <br /> solinoid. <br /> PSP-0029 MJN 12/28/20 01215MJNI WEST SUMP PUMP IS RUNNING ALL THE TIME.---Replaced <br /> float switch. <br /> TI-157 PJS 11/6/20 01 105BGW 1 TEMP SHOWN JUMPING AROUND BETWEEN 99.3 AND 99.5 <br /> AT A CONSTANT PACE. Left PC mounted multiturn potentiometer <br /> behind faceplate has an oxidized point of contact between wiper and <br /> trace. Wiping the pot does not fix the problem. Moved point of <br /> contact away from oxidized point.Now OK. DCS reading 99.1 Deg F <br /> and Red Lion APLCL401 indicator reading 99.0 Deg F. <br /> T1-157 PJS 12/1/20 01123BGW1 THE READOUT IS JUMPING OUT A LOT. Issue happened again. <br /> Replaced indicator with a used unit.Now OK. <br /> See W/O 01105BGW 1:TEMP SHOWN JUMPING AROUND <br /> BETWEEN 99.3 AND 99.5 AT A CONSTANT PACE. Left PC <br /> mounted multiturn potentiometer behind faceplate has an oxidized <br /> point of contact between wiper and trace. Wiping the pot does not fix <br /> the problem. Moved point of contact away from oxidized point.Now <br /> OK. DCS reading 99.1 Deg F and Red Lion APLCL401 indicator <br /> reading 99.0 Deg F. <br /> VFD004DS02 MJN 1/24/20 00121JMG1 THE"0" KEY ON THE HIM IS NOT WORKING.---Replaced <br /> keypad.all ok. <br /> VFD004DS03 MJN 5/11/20 00509JMG 1 THE"0" KEY ON CONTROL PANEL IS NOT <br /> • WORKING.---Replaced keypad. <br /> VFD004DSO4 MJN 8/18/20 00815KJW 1 NO POWER TO VFD---Reset breaker in VFD panel <br /> Page 3 of 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.