Laserfiche WebLink
The grade away from foundation <br />walls shall fall a minimum of 6 <br />in. within the first l0 ft., <br />except as restricted by lot <br />lines where the fall will be <br />minimum of 6 in. regardless <br />the horizontal distance <br />available. <br /> <br /> Basement walls, foundation <br /> walls, porches, c~rpor% slabs <br /> and steps exposed to the <br /> weather, and garage floor slabs <br /> shall have a minimum specified <br /> compressive strength of 3000. <br /> Table No. R-302.2 <br /> <br /> Footings sections: 1~ in. wide <br /> - 1 story; 15 in.- 2 story, 18 <br /> in. 3 story. Footzngs~h~l <br /> ex%end not less than ~in. <br /> below the finish natural grade. <br /> R-303 <br /> <br /> ~ Foundation walls shall extend <br /> at least 8 in. above the <br /> finished grade to the founda- <br /> tion at all points. R~304.2 <br /> <br /> 5. Masonry and concrete foundation <br /> wails shall be constructed <br /> using the following criteria: <br /> <br /> rai s-shall be pro'v£de <br />all concrete or masonry founda~ <br />tions. Perforated pipe or other <br />approved systems or materials <br />shall be installed at or below <br />the area to be pr'elected and <br />shall discharge by gravity or <br />mechanical means into an <br />approved drainage system. R- <br />3~5.1 <br /> <br />Exterior foundation walls of <br />masonry construction enclosing <br />basements shall be dampproofed, <br />Founda=ion walls of habitable <br />rooms located below grade shall <br />be waterproofed. R-306.1 <br /> <br />The minimum net area of' venti- <br />lation openings shall be not <br />less than 1 sq. fi, for each <br />150 sq, ft. of crawl space <br />area. Openings shall be within <br />3 ft. of each corner of said <br />building, <br /> <br />An access crawl hole lS in. by <br />24 in. shall be p~o~ided to the <br />underfloor space. R-309,2 <br /> <br />The under floor grade shall be <br />cleaned of all vegetation and <br />organic materials. R-309.3 <br /> <br />Bathrooms shall be provided <br />wi~h artificial light and an <br />approved mechsnical ventila- <br />t ion system capable o f <br />producing a change of air <br />every 12 minutes or a window <br />of not less than 3 sq. <br /> one-half of which must be <br /> operable. R-203,3 <br /> <br />12. <br /> <br /> Every sleeping room shall have <br /> an ex~erior door or not less <br /> than 5.7 sq. ft. of openable <br /> window, The min. net clear <br /> opening height shall be 24 <br /> inches. The min. net clear <br /> opening width shall be <br /> inches. The finished sill <br /> height shall be not more then <br /> 44 inches. R-210.2 <br /> <br /> 13. Ail habitable rooms shall be <br /> provided with aggregate <br /> glazing area of not less than <br /> 8 percen~ of the floor area of <br /> such rooms. One-half of <br /> required area of glazing shall <br /> be openable. <br /> <br />Where bottom of glass light is <br />within 18 in. of floor and all <br />glass doors and wall panels of <br />bathtub and shower enclosures, <br />must be of laminated, tempered <br />or wire glass. R-208.4 <br /> <br /> Openings between the garage <br /> and residence shall be <br /> equipped with solid wood doors <br /> not less than I 3/8 in, in <br /> ghickness or equivalent <br /> 209.1 <br /> <br /> The garage shall be compleSely <br /> separated from ~he residence <br /> and its at~ic area by means of <br /> 1/2 in. gypsum board or <br /> equivalent applied ~o the <br /> garage side. R-209.2 <br /> <br /> 17, NO= less than one exit shall <br /> be provided from each dwelling <br /> unit. The required exit door <br /> ~hall be a side-hinged door <br /> and not less than 3 ft in <br /> width and 6 ft 8 in. iD h~. <br /> 211 <br /> <br /> 18. Stairways shall no~ be less <br /> than 3 ft in clear width, and <br /> the headroom shall be 6 ft 8 <br /> in min,, rise 8 1/4 max., and <br /> run of 9 in, min. R-213.1 <br /> <br /> 19, Handrails having min. and max. <br /> heights of 30 in. and 34 in. <br /> respectively, measured~ <br /> vertically from the nosing of <br /> the treads, shall be provided <br /> on at least one side of <br /> .stairways of three or more <br /> rises and shall be continuous <br /> the full length of the stairs <br /> and shall extend 6 inches <br /> beyond the top and bottom <br /> rises, Ends shall be returned <br /> or shall terminate in newel <br /> post or safety terminals. <br /> 214.1 <br /> <br /> <br />