Permits
Permit Address
860 9TH ST
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
12734
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
The grade away from foundation <br />walls shall fall a minimum of 6 <br />in. within the first l0 ft., <br />except as restricted by lot <br />lines where the fall will be <br />minimum of 6 in. regardless <br />the horizontal distance <br />available. <br /> <br /> Basement walls, foundation <br /> walls, porches, c~rpor% slabs <br /> and steps exposed to the <br /> weather, and garage floor slabs <br /> shall have a minimum specified <br /> compressive strength of 3000. <br /> Table No. R-302.2 <br /> <br /> Footings sections: 1~ in. wide <br /> - 1 story; 15 in.- 2 story, 18 <br /> in. 3 story. Footzngs~h~l <br /> ex%end not less than ~in. <br /> below the finish natural grade. <br /> R-303 <br /> <br /> ~ Foundation walls shall extend <br /> at least 8 in. above the <br /> finished grade to the founda- <br /> tion at all points. R~304.2 <br /> <br /> 5. Masonry and concrete foundation <br /> wails shall be constructed <br /> using the following criteria: <br /> <br /> rai s-shall be pro'v£de <br />all concrete or masonry founda~ <br />tions. Perforated pipe or other <br />approved systems or materials <br />shall be installed at or below <br />the area to be pr'elected and <br />shall discharge by gravity or <br />mechanical means into an <br />approved drainage system. R- <br />3~5.1 <br /> <br />Exterior foundation walls of <br />masonry construction enclosing <br />basements shall be dampproofed, <br />Founda=ion walls of habitable <br />rooms located below grade shall <br />be waterproofed. R-306.1 <br /> <br />The minimum net area of' venti- <br />lation openings shall be not <br />less than 1 sq. fi, for each <br />150 sq, ft. of crawl space <br />area. Openings shall be within <br />3 ft. of each corner of said <br />building, <br /> <br />An access crawl hole lS in. by <br />24 in. shall be p~o~ided to the <br />underfloor space. R-309,2 <br /> <br />The under floor grade shall be <br />cleaned of all vegetation and <br />organic materials. R-309.3 <br /> <br />Bathrooms shall be provided <br />wi~h artificial light and an <br />approved mechsnical ventila- <br />t ion system capable o f <br />producing a change of air <br />every 12 minutes or a window <br />of not less than 3 sq. <br /> one-half of which must be <br /> operable. R-203,3 <br /> <br />12. <br /> <br /> Every sleeping room shall have <br /> an ex~erior door or not less <br /> than 5.7 sq. ft. of openable <br /> window, The min. net clear <br /> opening height shall be 24 <br /> inches. The min. net clear <br /> opening width shall be <br /> inches. The finished sill <br /> height shall be not more then <br /> 44 inches. R-210.2 <br /> <br /> 13. Ail habitable rooms shall be <br /> provided with aggregate <br /> glazing area of not less than <br /> 8 percen~ of the floor area of <br /> such rooms. One-half of <br /> required area of glazing shall <br /> be openable. <br /> <br />Where bottom of glass light is <br />within 18 in. of floor and all <br />glass doors and wall panels of <br />bathtub and shower enclosures, <br />must be of laminated, tempered <br />or wire glass. R-208.4 <br /> <br /> Openings between the garage <br /> and residence shall be <br /> equipped with solid wood doors <br /> not less than I 3/8 in, in <br /> ghickness or equivalent <br /> 209.1 <br /> <br /> The garage shall be compleSely <br /> separated from ~he residence <br /> and its at~ic area by means of <br /> 1/2 in. gypsum board or <br /> equivalent applied ~o the <br /> garage side. R-209.2 <br /> <br /> 17, NO= less than one exit shall <br /> be provided from each dwelling <br /> unit. The required exit door <br /> ~hall be a side-hinged door <br /> and not less than 3 ft in <br /> width and 6 ft 8 in. iD h~. <br /> 211 <br /> <br /> 18. Stairways shall no~ be less <br /> than 3 ft in clear width, and <br /> the headroom shall be 6 ft 8 <br /> in min,, rise 8 1/4 max., and <br /> run of 9 in, min. R-213.1 <br /> <br /> 19, Handrails having min. and max. <br /> heights of 30 in. and 34 in. <br /> respectively, measured~ <br /> vertically from the nosing of <br /> the treads, shall be provided <br /> on at least one side of <br /> .stairways of three or more <br /> rises and shall be continuous <br /> the full length of the stairs <br /> and shall extend 6 inches <br /> beyond the top and bottom <br /> rises, Ends shall be returned <br /> or shall terminate in newel <br /> post or safety terminals. <br /> 214.1 <br /> <br /> <br />