My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1274110
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1274110
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2011 10:23:11 AM
Creation date
9/3/2003 11:17:17 AM
Metadata
Fields
Template:
Permits
Permit Address
860 9TH ST
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
12734
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
20. Porches, balconies or raised <br /> floor surfaces located more <br /> than 30 in. above the floor or <br /> grade shall have guardrails not <br /> less than 36 in. in hr. <br /> Required guardrails shall have <br /> intermediate rails or ornamen- <br /> tal closures which will not <br /> allow passage of an object <br /> in. or more in diameter. R- <br /> <br />21. ~moke detectors shall <br /> installed outside of each <br /> separate sleeping area in the <br /> immediate vicinity of the <br /> bedrooms and on each additional <br /> story of the dwelling including <br /> basements. In dwelling units <br /> with split levels, a smoke <br /> detector need be installed only <br /> on the upper level, provided <br /> the lower level is less than <br /> one full story below the upper <br /> level, except that if there is <br /> a door between levels then a <br /> detector is required on each <br /> level. All detectors shall be <br /> connected to a sounding device <br /> or other detectors to provide, <br /> when actuated, an alarm which <br /> will be audible in all sleeping <br /> areas. R-215.1 <br /> <br /> 22. In new construction, required <br /> smoke detecnors shall receive <br /> their primary power from the <br /> building wiring. Smoke detec- <br /> tors may be battery operated <br /> when installed in existing <br /> buildings. R-215.2 <br /> <br /> 23. Firestopping Sheik' be provided <br /> in the following locations: in <br /> concealed spaces of stud walls <br /> at the ceiling, floors,soffits, <br /> drop ceilings, between stair <br /> stringers and at openings <br /> aro~nd vents, pipes, ducts, <br /> chimneys and fireplaces'at <br /> ceiling and floor spaces. <br /> 402.7 <br /> <br />Foundation cripple walls shall <br />be framed of studs with a min. <br />length of 14 in. or shall, be <br />framed of solid blocking. R- <br />402.9 <br /> <br />The area within the foundation <br />walls shall have all vegeta- <br />tion, top soil and foreign <br />material removed. R-603~2 <br /> <br />Rafters shall be- nailed to <br /> to form 'a con- <br />tinuous tie between exterior <br />walls where joist are parallel <br />to the rafters. Where not <br />parallel, rafters shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter ties shall be spaced not <br />more than 4 feet on center. <br /> <br /> less in depth than the cut end <br /> of the rafter. At all valleys <br /> and hips there shall be <br /> valley or hip rafter not less <br /> than 2 in. nominal thickness <br /> and not less in depth than the <br /> cut end of the rafter. R-702.2 <br /> 28. when the roof pitch is less <br /> khan 3 in 12, members support- <br /> ing rafters and ceiling joist, <br /> such as ridge beams, hips and <br />/valleys, shall be designed as <br /> beams. R-7O2.3 .. <br /> <br /> Wooa trusses shall be designed <br /> in accordance with approved <br /> engineering practice. Trusses <br /> shall be braced according <br /> their appropriate engineered <br /> design. Truss members shall <br /> not be cut or altered unless <br /> so designed. R-702.9 <br />~0~. Ail plywood, when designed <br /> be exposed in outdoor applica- <br /> tions shall be of an exterior <br /> type, except that plywood roof <br /> sheathing exposed to the <br /> underside may be of interior <br /> type with exterior 91ne. <br /> 703.1 <br /> <br /> Provide Screened attic vents <br /> with a ~et free area of 1/150 <br /> of the attic area [or 1/300 if <br /> half is along eaves and the <br /> other half in the upper <br /> portion) ~ R-707 <br /> <br /> 32.~A~-'r'eadily accessible attic <br /> access framed opening not less <br /> than 22 in. by 30 in. shall be <br /> provided. R-708 <br /> <br /> 33. Fireplace and chimney con- <br /> s~ruction shall conform to <br /> chapter 9. <br /> <br /> 34. INSULATION REQUIREMBNTS: <br /> Buildings with high-efficiency <br /> heating equipment shall be <br /> insulated as follow: ceiling <br /> R-30 (roof/ceiling assemblies <br /> in which has a slope of $ in <br /> 12 or greater, may be R-19), <br /> walls R-11, underfloor$ R-19, <br /> other heating systems, ceiling <br /> R-38 (vaulted ceiling R-19) <br /> walls [{-19 and under floor R- <br /> 19. <br /> <br />Elements of appliances which <br />create a glow, spark or flame <br />shall be located a min. of 18 <br />in. above garage floor. Mu <br />1114 <br /> <br />Appliances subject to mechani- <br />cal damage shall be guarded by <br />a protecti, ve barrier. M-1114 <br /> <br />· Ridge board shall be at least 1 <br /> inch nominal thickness and not' <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.