My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1276328
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 3
>
Permit - 1276328
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2011 2:23:37 PM
Creation date
9/3/2003 12:17:38 PM
Metadata
Fields
Template:
Permits
Permit Address
275 SANTIAM AV W
Permit City
Detroit
Parcel Number
105E02DA02200
Permit Type
Permit
Permit Site Number
13524
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
275 santiam Ave., Detroit <br />July 23, 1991 <br />Page 2 <br /> <br />10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />c) <br /> <br />D) <br /> <br />At all interconnections between concealed vertical and <br />horizontal spaces such as occur at soffits, drop ceilings <br />etc.~ <br />In concealed spaces between stair stringers at the top and <br />bottom of the run; <br />At openings around vents, pipes ducts, chimneys and <br />fireplaces at ceiling and floor level, <br />with noncombustible materials. (R-402.7) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the inunediate vicinity of the bedroom. All detectors shall be <br />connected to a sounding device or other detector~ to provide, when <br />actuated, an alarm which will be audible in all sleeping areas. <br />(R-215.1) <br /> <br />Provide screened attic vents with a net free area of 1/150 of the attic <br />area (or 1/300 if half is along eaves and the other half in the upper <br />portion). (R-707) <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of OVer 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />INSULATION REQUIREMENTS: Provide insulation as follows: ceiling R-38 <br />(vaulted ceiling R-19) walls R-19 and under floor <br /> <br />Buildings with high-efficiency heating equipment (Heat Pumps w/ <br />COP of 2.7 Or Gas or Oil w/ 80% AFUE rating) may be insulated as <br />follows: ceiling R-30 (roof/ceiling assemblies in which has a <br />slope of 3 in 12 or greater, may be R-19), walls R-11, underfloors <br />R-19. <br /> <br />Windows, skylights and sliding doors are require a tested U factor of <br />0.65 BTU/hour/sq. ft./degree F. windows must be labeled indicating the <br />appropriate U factor. Exterior doors are required to have a U factor of <br />0.54 or less. (Sec. 5303(c)2 & 3) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.