My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1276890
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1276890
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2011 3:45:49 PM
Creation date
9/3/2003 12:38:21 PM
Metadata
Fields
Template:
Permits
Permit Address
9978 STAYTON RD SE
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
14869
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
9978 Stayton Road SE, Aumsville <br />December 2, 1991 <br />Page 2 <br /> <br />10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. All detectors shall be connected to a sounding <br />device or other detectors to provide, when actuated, an alarm which will <br />be audible in all sleeping areas. (R-215.1) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring. Smoke detectors may be battery <br />operated when installed in existing buildings. (R-215.2) <br /> <br />Bathrooms shall be provided with artificial light and an approved <br />mechanical ventilation system capable of producing a change of air every <br />12 minutes or a window of not less than 3 sq. ft., one-half of which <br />must be openable. (R-203.3) <br /> <br />Wood framed walls less than four feet in width at garage door openings <br />shall be provided with approved hold-down anchors. Anchors are to be <br />provided at each end of each wall segment and connect the wall studding <br />to the concrete foundation. As an alternate, a designed structural <br />system to resist the required 80 mile per hour wind load can be <br />provided. <br /> <br />Provide attic ventilation. The net free ventilating area shall be not <br />less than 1 to 150 of the area of the space ventilated. (R-307) <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />~ngineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. Ail job site cutting or <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the job site, submit the engineer's design and construction plans to <br />the Marion County Building Department prior to start of construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.