Laserfiche WebLink
8851 Smith Road SE <br />November 3, 1992 <br />Page 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNITY DEVELOPMI~N~ <br />[])E PA~,TMENT <br /> <br />Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1990 Edition One and Two Family Dwelling Specialty Code. <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />fronting the property. (UFC 10.208) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines whsre the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Foundation plates shall be bolted to the foundation with minimum <br />1/2 inch diameter by l0 inch anchor bolts embedded at least 7 inches <br />into concrete or reinforced masonry and spaced not more than 6 feet <br />apart with a minimum of 2 bolts per piece with one bolt within 12 inches <br />of the end of each piece. Figure (R-303) <br /> <br />Provide at least 1 square foot of underfloor ventilation for each 150 <br />~quare feet of crawl space area. The openings shall be covered with a <br />corrosion resistant wire mesh. At least one such opening shall be <br />provided within 3 feet of each corner of the building. (R-309.1) <br /> <br />Stairways shall not be less than 3 feet in clear width and the headroom <br />shall not be less than 6 feet 8 inches. The minimum required stair <br />tread width is 9 inches. The maximum stair rise is $ 1/4 inches. All <br />treads shall have a nosing Or effective projection of approximately 1 <br />inch when risers are closed. 9he greatest riser height shall not exceed <br />the smallest by more than 3/8 inch. (R-213.1) <br /> <br />Handrails meeting the following requirements shall be provided on at <br />least one side of stairways. The handgrip portion of handrails shall be <br />not more than 2 5/8 inches in cross-sectional dimension, or the shape <br />shall provide an equivalent gripping surface, Handrails shall be <br />mounted between a minimum of 30 inches and a maximum of 38 inches. They <br />shall be continuous the full length of the stairs. Ends shall be <br />returned ox shall terminate in newel posts ox safety terminals. <br />(R-214.1) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be mo~e <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />"APPRO1~.ED~" only when this sheet is attached to plans <br /> <br /> <br />