PP~ESSURIZED DISTRIBUTION SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />November 30, 1992 <br /> <br />APPLICANT: <br />SITS NUMBER= <br /> <br />ALTERNATIVE <br />shall apply <br /> <br /> KENNETH ALLEN <br /> 92-3802 <br /> ORIGINAL SYSTEM <br /> <br />site has been found suitable for a PRESSURIZED DISTRIBUTION <br />SEWAGE DISPOSAL SYSTEM. The following construction specifications <br />to the installation of your septic system. <br /> <br />The septic tank shall have a minimum liquid capacity of <br />gallons. <br /> <br />The projected daily sewage flew for this project is calculated at <br />450 qallons pe~. day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 75 lineal f.eet per 1~0 <br />~allons of projected daily sewage flow. A minimum of 225 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br />The disposal field piping is minimum two (2) inch pressure piping, <br />with a minimum 160 psi rating. The sidewalls of the disposal <br />trenches and top of the filter material shall be lined with filter <br />fabric. <br /> <br />The disposal field shall be constructed with pressurized equal <br />distribution with a minimum trench depth of 18 inches and a <br />maximum trench depth of 18 inches. There must be at least 6 inches <br />of backfill ewer the top of the gravel, measured from the natural <br />ground surface, <br /> <br />An effluent lift pump or siphon which is sized to provide a <br />minimum residual head of five (5) feet at the most distant orifice <br />is required <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new sit~ evaluation may be required if the system is <br />proposed for a dkfferent a~ea on the property. <br /> <br />SPECIAL CONDITIONS: <br /> This system must only be constructed on the highest ground within the <br /> immediate area of the southeasterly test pit. The alternative sand <br /> filter system must be constructed within the immediate area of the other <br /> two new test pits. Observe all normal setback/separation distances. <br /> Refer to the enclosed setback list which outlines minimum setbacks <br /> between septic systems and other features. A pre-constructioa field <br /> stakeout is recommended prior to any construction and excavation. I <br /> eugqest that the well construction be deferred until the location of th~ <br /> individual drainfield lines have been confirmed and approved by our <br /> department. <br /> <br />THIS Is NOT A PERMIT TO INST.?3. THE SEPTIC SYSTEM. DO NOT INSTALL THE SYSTEM <br />UNTIL A VALID PERMIT ~AS BEEN ISSUED EY THIS OFFICE. <br /> <br /> <br />