Laserfiche WebLink
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />DIRECTOR <br />Cra~§ O. Luedeman <br /> <br />I~UILDIN(: INSPECTION DATE: <br />(503) 58~-5147 <br /> SUBJECT~ <br />pILANNING & <br />ENFORCEMENT <br />(503) 588.5038 OWNER ~ <br /> <br />LIOA R D OF <br />COMMISSIONI]RS SITE NUMBER: <br />Randall [:rankc <br />Gary H~er <br /> <br /> BUILDING CLASS: <br /> <br />Of EiCER <br />K~!n Roudybush <br /> <br />PLAN REVIEW NOTICE <br /> <br />January 31, 1993 <br /> <br />9493 Porter Rd SE, Aumsville <br />Modern Building Systems Plant Alteration <br /> <br />Modern Building Systems <br />93-28 <br /> <br />TYPE OF CONSTRUCTION: <br /> <br />5-N / Fully Sprinklered <br /> <br />(Prefab. Bldg. Mfg.) <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a Plan Review covering the construction of the additions and <br />alterations (24,600 sq. ft.) to the above indicated building (Approx. Total: <br />130,500 sq.ft.). The plans have been checked for compliance with the <br />provisions of the Oregon State Structural Specialty Code (UBC) 1993 Edition. <br /> <br />This review is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in the <br />plans and structural calculations is beyond the scope of this review. <br /> <br />The building exceeds the floor area limits set forth in Table No. 5-C. <br />The floor area of a Group B occupancy, one or two story building <br />specified in Section 506(b) may be unlimited where 60 foot yards <br />entirely surround the proposed construction and where an approved <br />automatic fire sprinkler system is installed throughout the building. <br />(506) A "yard" is an open, unoccupied space unobstructed from the <br />ground to the sky on the lot on which a build--ted. (426) <br />Show the dimensions of the designated yards on the site plan for fire <br />protection purposes. <br /> <br />Warehouses and factories or workshops using materials not highly <br />flammable or combustible are classified as Group B Division 2 <br />Occupancies (B-2). Based on the information submitted with the plans, <br />this building has been classed as a E-2 Occupancy. The use or storage <br />of highly flammable or combustible materials or accumulations of <br />combustible dust greater than 1 lb. per 1,000 cu. ft. would cause the <br />occupancy classification to be changed and additional code requirements <br />may be necessary. Contact Marion County Building Inspection if this <br />occupancy classification is not appropriate to your intended use of the <br />facility. (701) <br /> <br />The use, handling and sale of Class I, II and III-A flammable liquids <br />shall be in accordance with the fire code. (708) <br /> <br />Senator Building . 220 High Street NE · Salem, Oregon 97301-3670 <br /> <br /> <br />