Laserfiche WebLink
980 Cleveland, Aumsville <br />October 13t 1993 <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br />18. <br /> <br />Every sleeping room sha)}.have at ~east one ~operable window approved for <br />emergency egres~ or res~e~ ~he w{~w ~il~ height shall net be more <br />than 44 inches above th~ floo~ T~e'~ini~ net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />Firestopping shall be provided in the following locations: in concealed <br />spaces of stud walls at the ceiling, floors, soffits, drop ceilings, <br />between stair stringers and at openings around vents, pipes, ducts, <br />chimneys and fireplaces at ceiling and floor spaces. (R-402.7) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent applied to <br />the garage side. The door between the garage and residence shall be <br />equipped with solid wood doors not less than I 3/8 inches in thickness <br />or 20-minute fire rated, Or equivalent. (R-209.2) <br /> <br />Water heaters having nonrigid water connections and over 4-feet in <br />height from the base to the top of the tank case shall be anchored or <br />strapped to the building to resist horizontal displacement due to <br />earthquake motion. (M-1006.2) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. (R-215.2) <br /> <br />Wood framed walls less than four feet in width at garage door openings <br />shall be provided with approved hold-down anchors. Anchors are to be <br />provided at each end of each wall segment and connect the wall studding <br />to the concrete foundation. As an alternate, a designed structural <br />system to resist the required 80 mile per hour wind load can be <br />provided. <br /> <br />A readily accessible attic access shall be p~ovided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the ~ob eite, ~ubmit %he engineer's design and construction plans to <br />the Marion County Building Department prior to start of construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />Factory built chimneys shall conform to the conditions of their listing <br />and the manufacturer's instructions. (R-902) <br /> <br />Factory-built fireplace stoves, consisting of a freestanding fire <br />chamber assembly, that have been tested and are listed by a nationally <br />recognized testing laboratory, shall be installed in accordance with the <br />requirements of said listing and the manufacturer's instructions. <br />(R-905) <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />