Laserfiche WebLink
11769 Warbler Lane NE, Aurora <br />September 2, 1993 <br />Page 2 <br /> <br />TABLE NO. R-402.10 <br /> <br />CONDITION 1 TYPE OF BRACE A~OUNT OF BRACING 2 3 <br />One Story. 1-by 4-inch let-in Located at each end and <br />Top of two or three bracing or structural at least every 25 feet <br />story. .... shear h.~g. o f ....w..9~ 1 length. <br /> <br />First story of two Structural sheathing. 25 percent of wall <br />story, length to be sheathed. <br />Second story of three <br />story~ <br />First story of three Structural sheathing. 40 percent of wall <br />story. . ....... length to be sheathed. <br /> <br /> Foundations wall panels braced sa~ae as story above. <br /> where structural sheathing is used, each braced panel must be at least 48 <br /> inches in width. <br />3 Structural sheathing and let-in bracing shall be located at each end or as <br /> near thereto as possible. <br /> <br />Submit revised plans showing that the structure is designed to the current <br />code as a free-standing structure. <br /> <br />S I NCER~LY, <br />SANDRA FREILINGER ~ <br />PLAN EX/LMINER <br /> <br />DON WOODLE~ <br />BUILDING OFFICIAL <br /> <br />file <br /> <br /> <br />