My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1284501
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1284501
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2011 11:58:04 AM
Creation date
9/3/2003 4:24:16 PM
Metadata
Fields
Template:
Permits
Permit Address
9150 SMITH RD SE
Permit City
Aumsville
Permit Number
94-00065
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SAND F??,~ SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />August 31, 1992 <br /> <br />APPLICANT= <br />SITE NUMBER: <br /> <br />EAROLD M. SMITH <br />92-2999 <br /> <br />REPLACEMENT SYSTEM <br /> <br /> Your site has been found suitable for a SAND FILTER ALTERNATIVE SEWAGE <br />DISPOSAL SYSTEM. The following construction specifications shall apply to the <br />installation of your septic system. <br /> <br />The septic tank shall have a minimum liquid capacity of 1000 <br />gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />4~0 qallons pp~ day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 50. lineal feet p~ 150 <br />gallons of projected daily sewage flow. A minimum of 150 l~eal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (~1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with serial distribution <br />with a minimum trench depth of ~4 inches and a maximum trench <br />depth of 24 inches. There must be at least 12 inches of backfill <br />over the top of the gravel, measured from the natural ground <br /> <br />The sand filter system shall be designed and operated as per OAR <br />340-71-290 through 340-71-305. Detailed plans for the system must <br />be submitted prior to permit issuance. A building permit is <br />required if a site built concrete box is used as the sand filter <br />container. A pamphlet is available in our office which details the <br />requirements for a sand filter system. <br /> <br /> A groundwater interceptor is required as part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 36 <br />inches deep with 30 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> This drainfield should be constructed as far up slope as possible within <br /> the area of the soil test pits. There is a moderate rock hazard associ- <br /> ated with drainfield construction. Rock larger than six inches must be <br /> removed from backfill material. Refer to the enclosed setback list which <br /> outlines minimum separation distances between components of septic <br /> systems and other features. Soil conditions are marginal for drainfield <br /> construction, so summer season construction is recommended. <br /> <br />THIS IS NOT A PERMIT TO INSTALL TEE SEPTIC SYSTEM. DO NOT INSTa?~, THE SYSTEM <br />UNTIL A VALID PERMIT ~A$ BEEN ISSD-ED BY THIS OFFICE. <br /> <br /> <br />