790 Main st, Aumsville <br />September 7, 1994 <br />Page 4 <br /> <br /> doorway. Landings shall be level except for exterior landings, which <br /> may have a slope not to exceed 1/4 inch per foot. (3304)(i)) <br /> <br />22. Handles, pulls, latches, locks and other operating devices on doors, <br /> windows, cabinets, plumbing fixtures and storage facilities shall have <br /> lever or other shape permitting operation by wrist or arm pressure and <br /> not requiring tight grasping, pinching or twisting to operate. The <br /> force required to activate such equipment shall be no greater than 5 <br /> pounds-force. Doors shall comply with Section 3304 of the 1991 U.B.C. <br /> (3109(c)} <br /> <br />23. Buildings which require that toilet facilities be provided shall have at <br /> least one standard accessible facility with an accessible water closet <br /> and an accessible lavatory. Where mirrors, towel fixtures and other <br /> toilet and bathroom accessories are provided, at least one of each shall <br /> be accessible. (3108) <br /> <br />24. Insulation and vapor barriers when exposed are to have a flame spread <br /> rate not to exceed 25. (1713) <br /> <br />25. A one-perm vapor barrier shall be installed on the warm side (in winter) <br /> in all exterior walls and ceilings of heated buildings. (5303(f)) <br /> <br />26. The mechanical plans have not been submitted and are not covered by this <br /> review. Mechanical systems, when installed, are required to be in <br /> compliance with applicable codes. <br /> <br />27. Provide an exhaust fan that is connected directly to the outside for the <br /> toilet rooms. A mechanically operated exhaust system shall provide a <br /> complete air change every 15 minutes (_05) <br /> <br />28. An attic access opening shall be provided to attics of buildings with <br /> combustible ceiling or roof construction where the maximum attic height <br /> is more than 30 inches. The opening shall be located in a Corridor, <br /> hallway or other readily accessible location. Provide an attic access <br /> opening not less than 22 inches by 30 inches. Thirty-inch minimum clear <br /> head room shall be provided above the access opening. (3205(a)) <br /> <br />29. Enclosed attics and enclosed rafter spaces formed where ceilings are <br /> applied directly to the underside of roof rafters shall have cross <br /> ventilation for each separate space. The net free ventilating area <br /> shall be not less than 1/150 of the area of the space ventilated. <br /> (3205(c)) <br /> <br />30. Approved numbers or addresses shall be provided for all new buildings in <br /> such a position as to be plainly visible and legible from the street or <br /> road fronting the property. (513) (UFC 10.301) (ORD 774) <br /> <br />31. Storage and use of flammable and combustible liquids shall be in <br /> accordance with the Fire Code. (708) <br /> <br />32. A water supply sufficient to control a potential fire is required. See <br /> Appendix III-A of the Uniform Fire code. Contact the local fire <br /> department for requirements. The chief shall establish the minimum <br /> residual pressure and flow duration when determining fire flow. (U.F.C. <br /> 10.401) <br /> <br /> <br />