Laserfiche WebLink
$~EPAGE TI~NCH SYSTEM CONSTRUCtiON DETAIL SHEET <br />OCtober 13, 1992 <br /> <br />APPLICANT; JEFFPd~M CHASE <br />SITE NUMSER: 92-3358 <br /> <br /> Your site has been found suitable for a SEEPAGE TRENCH ALTERNATIVE <br />SEWAGE DISPOSAL SYSTEM. The following construction specifications shall apply <br />to the installation of your septic system. <br /> <br />The septic tank shall have a minimum liquid capacity of 1000 <br />gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />300 ~allons per day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 72 .~ineal feet per 150 <br />q~..llons of projected daily sewage flow. A minimum of 144 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with serial distribution <br />with a minimum trench depth of 42 inches and a maximum trench <br />depth of 42 inches. The depth Of filter below the distribution <br />pipe shall be 24 inches. There must be at least 12 inche~ of <br />backfill over the top of the gravel, measured from the natural <br />ground surface. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS= <br /> A detailed field stakeout of all proposed development is recommended, <br /> with a review by our department prior to construction and/or excavation. <br /> Use extreme care in siting the building and individual drainfield lines <br /> to ensure minimum required separation distances are maintained. Refer to <br /> the enclosed setback list which outlines minimum separation distances <br /> between components of septic systems and other features~ existing and <br /> proposed. The driveway access must be from the road easement along the <br /> northerly property line. NO further cuts will be allowed on the souther- <br /> ly portion of the property. Keep in mind that a full drainfield replace- <br /> ment area must be maintained with the soil in its natural undisturbed <br /> condition. <br /> <br />TNIS iS NO~ A PERMIT TO INSTALL TEE SEPTIC SYSTEM. DO NOT INSTALL THE SYSTEM <br />_UNTIL A V~LID PERMIT HAS BEEN ISSUED bY THIS OFFICe. <br /> <br /> <br />