Laserfiche WebLink
SHEARWALL CONSTRUCTION SCHEDULE <br /> <br />TYPICAL EXTERIOR SHEATHED WALLS <br />FRAMING - 2X6 AT 16" O,C. PROVIDE BLOCKING AT ALL PLYWOOD PANEL JOINTS, <br />SILL PLATE/ANCHORAGE - PRESERVATIVE TREATED 2X6 WITH 5/8" DIA, X 10" A.B. AT 48" D.C. <br />SHEATHING -MIN. 15/32" INDEX 24/0 CDX PLY~NOOD <br />FASTENERS - 8d COMMON NAILS OR 14 GA. X 2" X 7/16" CROWN STAPLES <br />FASTENER SPACING - 6" O,C, ALONG PLYWOOD PANEL EDGES, 12" O.C. IN FIELD <br /> <br />SHEARWALL #1 (SW-1) <br />PER DETAIL 1/12 <br /> <br />SHEARWALL #2 (SW-2) <br />PER DETAIL 1/11 <br /> <br />INTERIOR SHEARWALL #3 (SW-3) <br />FRAMING - AS REQUIRED BY CODE. PROVIDE BLOCKING AT ALL PLYWOOD PANEL JOINTS. <br />SILL PLATE/ANCHORAGE - SEE DETAIL 1/18 <br />SHEATHING - MIN. 15/32" INDEX 24/0 CDX PLYWOOD ' <br />FASTENERS - 8d COMMON NAILS OR 14 GA. X 2" X 7/16" CROWN STAPLES <br />FASTENER SPACING - 6" O.C. ALONG PLYWOOD PANEL EDGES, 12" O.C. IN FIELD <br /> <br />ALTERNATE INTERIOR SHEARWALL #3 (SW-3) <br />FRAMING - ~ 0;6. PROVIDE BLOCKING AT ALL PANEL JOINTS, <br />SILL PLATE/ANCHORAGE - SEE DETAIL 1/18 <br />SHEATHING - 1/2" GYPSUM, BOTH SIDES <br />FASTENERS - 5d COOLERS OR WALLBOARD NAILS <br />FASTENER SPACING - 4" O,C. EVERYWHERE <br />SHEARWALL#4 (SW,-.4) j~h~ ~-~'~ g~ <br />FRAMING - 2Y,~-A~(~. PROVIDE BLOCKING AT ALL PLYWOOD PANEL JOINTS, <br />SILL PLATE/ANCHORAGE - PRESERVATIVE TREATED 2X6 WITH 5/8" DIA, X 10" A,B. AT 24" <br />SHEATHING - MIN. 15/32" INDEX 24/0 CDX PLYWOOD <br />FASTENERS - 10d COMMON NAILS OR 14 GA. X 2" X 7/16" CROWN STAPLES <br />FASTENER SPACING - 4" O.C. ALONG PLYWOOD PANEL EDGES, 12" D.C. IN FIELD <br /> <br /> <br />