Laserfiche WebLink
PRESCRIPTIVE WALL BRACING <br /> <br />BRACED AND ALTERNATE BRACED WALL PANEL <br /> CONSTRUCTION SCHEDULE <br /> <br />BP (IEIRACED PANEL) 4' MIN. LENGTH <br />FRAMING - MEET CODE REQUIREMENTS FOR SIZE AND SPACING OF STUDS, <br />SILL PLATE/ANCHORAGE - PRESERVATIVE TREATED 2X WITH 1/2" DIA, X 10" A,B, AT 48" O,C. <br />SOLE PLATE/ANCHORAGE - MINIMUM 2X PLATE FASTENED TO FLOOR FRAMING WITH 16d <br /> COMMON NAILS AT 16" ON CENTER, <br />SHEATHING ~ MIN. 1/2" INDEX 24/0 CDX PLYWOOD PROVIDE 2" NOMINAL BLOCKING AT ALL <br /> PLYWOOD JOINTS. <br />FASTENERS - 8d COMMON NAILS OR 14 GA. X 2" X 7/16" CROWN STAPLES <br />FASTENER SPACING - 6" D.C. ALONG PLYWOOD PANEL EDGES, 12" O.C, IN FIELD <br /> <br />IBP (INTERIOR BRACED PANEL) 8' MIN. LENGTH <br />FRAMING - MEET CODE REQUIREMENTS FOR SIZE AND SPACING OF STUDS. <br />SOLE PLATE/ANCHORAGE - MINIMUM 2X PLATE FASTENED TO FLOOR FRAMING WITH 16d <br /> COMMON NAILS AT 16" ON CENTER, PROVIDE DOUBLE JOIST UNDER PARALLEL <br /> WALLS AND BLOCKING UNDER PERPENDICULAR WALLS, <br />SHEATHING - 1/2" GYPSUM APPLIED TO ONE SIDE OF WALL. PROVIDE 2" NOMINAL BLOCKING <br /> AT ALL PLYWOOD JOINTS. <br />FASTENERS/SPACING - 1 1/4" DRYWALL NAILS AT 7" ON CENTER, OR 1 1/4" TYPE W SCREWS <br /> AT 6" ON CENTER AT EDGES AND 12" ON CENTER IN FIELD, <br /> <br /> <br />